A New Means of Transcutaneous Coupling for Neural Prostheses
Bibliographic record
Abstract
Neural prostheses are electronic stimulators that activate nerves to restore sensory or motor functions. Implanted neural prostheses receive command signals and in some cases energy to recharge their batteries through the skin by telemetry. Here, we describe a new approach that eliminates the implanted stimulator. Stimulus pulse trains are passed between two surface electrodes placed on the skin. An insulated lead with conductive terminals at each end is implanted inside the body. One terminal is located under the cathodal surface electrode and the other is attached to a nerve targeted for stimulation. A fraction (10%-15%) of the current flowing between the surface electrodes is routed through the implanted lead. The nerve is stimulated when the amount of routed current is sufficient. The aims of this study were to establish some basic electrical properties of the system and test long-term stability in chronic implants. Stimulation of the nerve innervating the ankle flexors produced graded force over the full physiological range at amplitudes below threshold for evoking muscle contractions under the surface electrodes. Implants remained stable for over 8 mo. The findings provide the basis for a new family of neural prostheses.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".