MétaCan
Menu
Back to cohort
Record W2134251511 · doi:10.1148/radiol.2323030899

Reduced Radiation Dose Helical Chest CT: Effect on Reader Evaluation of Structures and Lung Findings

2004· article· en· W2134251511 on OpenAlexaff
John R. Mayo, Kun-Il Kim, Sharyn MacDonald, Takeshi Johkoh, Peter V. Kavanagh, Harvey O. Coxson, Sverre Vedal

Bibliographic record

VenueRadiology · 2004
Typearticle
Languageen
FieldMedicine
TopicRadiation Dose and Imaging
Canadian institutionsVancouver General HospitalUniversity of British Columbia
Fundersnot available
KeywordsMedicineMcNemar's testImage qualityNuclear medicineRadiologyTube (container)Image noiseChest tubeComputed tomographicCurrent (fluid)TomographyComputed tomographyImage (mathematics)StatisticsMathematicsArtificial intelligencePneumothorax

Abstract

fetched live from OpenAlex

PURPOSE: To assess, by using computer simulation, the effect of the use of reduced computed tomographic (CT) tube current on reader evaluation of structures and lung findings on images obtained at clinically indicated chest CT examinations. MATERIALS AND METHODS: The noise level in the raw scan data of 150 clinically indicated conventional tube current (200-320-mA) chest CT examinations was modified to simulate tube current reduction to 100 and to 40 mA. A total of 450 image sets were thus available. Four radiologists blinded to the tube current used assessed the image sets in random order for 14 structures and lung findings and ranked subjective image quality by using a five-point scale (1 = nondiagnostic, 2 = inferior, 3 = adequate, 4 = good, 5 = excellent). After a 3-week interval, the 150 conventional tube current image sets were rescored so that intraobserver agreement could be assessed. The McNemar statistic was used to determine whether there were more scoring disagreements between interpretations of the conventional and those of the reduced tube current scans or between the two interpretations of the conventional tube current scans. RESULTS: When overall agreement for 14 structures and lung findings was pooled over four observers, significantly more disagreements (P <.05) were seen when scores were compared between conventional and reduced tube current scans than when scores were compared between repeated interpretations of the conventional tube current scans. There was a significant decrease (P <.05) in the subjective image quality of reduced tube current scans compared with the subjective image quality of conventional tube current scans. CONCLUSION: These data indicate that reduced tube current does affect reader evaluation of structures and lung findings and reduces a reader's subjective assessment of image quality.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.767
Threshold uncertainty score0.322

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.331
Teacher spread0.312 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations57
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueRadiologySame topicRadiation Dose and ImagingFrench-language works237,207