MétaCan
Menu
Back to cohort
Record W2134695491 · doi:10.1213/ane.0b013e3181999339

Choosing a Lung Isolation Device for Thoracic Surgery: A Randomized Trial of Three Bronchial Blockers Versus Double-Lumen Tubes

2009· article· en· W2134695491 on OpenAlexaff
Manu Narayanaswamy, Karen McRae, Peter Slinger, Geoffrey Dugas, George W. Kanellakos, Andy Roscoe, Mélanie Lacroix

Bibliographic record

VenueAnesthesia & Analgesia · 2009
Typearticle
Languageen
FieldMedicine
TopicLung Cancer Diagnosis and Treatment
Canadian institutionsCredit Valley HospitalCégep de LévisUniversity of TorontoToronto General Hospital
Fundersnot available
KeywordsMedicineCardiothoracic surgeryIsolation (microbiology)Randomized controlled trialLungLumen (anatomy)SurgeryInternal medicineBioinformatics

Abstract

fetched live from OpenAlex

BACKGROUND: There is no consensus on the best technique for lung isolation for thoracic surgery. In this study, we compared the clinical performance of three bronchial blockers (BBs) available in North America with left-sided double-lumen tubes (DLTs) for lung isolation in patients undergoing left-sided thoracic surgery. METHODS: One hundred four patients undergoing left-sided thoracotomy or video-assisted thoracoscopic surgery were randomly assigned to one of the four lung isolation groups (n = 26/group). Lung isolation was with an Arndt wire-guided BB (Cook Critical Care, Bloomington, IN), a Cohen Flexi-tip BB (Cook Critical Care) or a Fuji Uni-blocker (Fuji Systems, Tokyo) or with a left-sided DLT (Mallinckrodt Medical, Cornamadde, Athlone, Westmeath, Ireland). Anesthetic management and lung isolation were performed according to a standardized protocol. Each group was randomly subdivided into two subgroups (n = 13/subgroup): immediate suction (at the time of insertion of the lung isolation device) (Subgroup I) or delayed suction (20 min after insertion of the lung separation device) (Subgroup D) according to when suction was applied to the BB suction channel or the bronchial lumen of the DLT. Using a verbal analog scale, lung collapse was assessed by the surgeons, who were blinded to the lung isolation technique. RESULTS: There was no difference among the lung isolation devices in lung collapse scores at 0 (P = 0.66), 10 (P = 0.78), or 20 min (P = 0.51) after pleural opening. The time to initial lung isolation was less for DLTs (93 +/- 62 s) than BBs (203 +/- 132) (P = 0.0001). There were no differences among the BBs in the time to lung isolation (P = 0.78). There were significantly more repositions after initial placement of the lung isolation device with BBs (35 incidents) than with DLTs (two incidents) (P = 0.009). The Arndt BB required repositioning more frequently (16 incidents) than the Cohen BB (8) or the Fuji BB (11) (P = 0.032). CONCLUSIONS: The three BBs provided equivalent surgical exposure to left-sided DLTs during left-sided open or video-assisted thoracoscopic surgery thoracic procedures. BBs required longer to position and required intraoperative repositioning more often. The Arndt BB needed to be repositioned more often than the other BBs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.006
Threshold uncertainty score0.020

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0040.006
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0050.003
Bibliometrics0.0000.000
Science and technology studies0.0010.002
Scholarly communication0.0020.001
Open science0.0010.001
Research integrity0.0030.004
Insufficient payload (model declined to judge)0.0060.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.033
GPT teacher head0.329
Teacher spread0.296 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations204
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueAnesthesia & AnalgesiaSame topicLung Cancer Diagnosis and TreatmentFrench-language works237,207