MétaCan
Menu
Back to cohort
Record W2135070940 · doi:10.1109/eic.2009.5166340

Case study - high ozone concentration in hydro generators

2009· article· en· W2135070940 on OpenAlexaff
Charles Millet, D.N. Nguyen, Louis Lépine, M. Bélec, Denise Lessard-Déziel, C. Guddemi

Bibliographic record

Venuenot available
Typearticle
Languageen
FieldMaterials Science
TopicHigh voltage insulation and dielectric phenomena
Canadian institutionsHydro-Québec
Fundersnot available
KeywordsOzoneStatorPartial dischargeElectromagnetic coilCoatingMaterials scienceCorona dischargeEnvironmental scienceElectrical engineeringNuclear engineeringVoltageComposite materialEngineeringPhysicsMeteorology

Abstract

fetched live from OpenAlex

Ozone emission in hydro generators is a sign of surface partial discharge (PD) in the stator windings. Surface PD activity can take different forms: slot PD, corona at the junction of the slot semiconductive coating with the voltage grading coating outside the slot, PD between adjacent coils in the end-winding, PD between adjacent connections and surface tracking. An ozone concentration above the daily exposure limit, for which there is a health hazard for workers, was found at several locations in a 6-hydro generator plant. The ozone level in the vicinity of the generators was in the same range for all of them. This case study presents how this problem was identified and addressed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.143
Threshold uncertainty score0.824

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.017
GPT teacher head0.260
Teacher spread0.242 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2009
Admission routes1
Has abstractyes

Explore more

Same topicHigh voltage insulation and dielectric phenomenaFrench-language works237,207