MétaCan
Menu
Back to cohort

The Efficacy of Farabloc, An Electromagnetic Shield, in Attenuating Delayed-Onset Muscle Soreness

2000· article· en· W2135085382 on OpenAlex
Jian Zhang, Douglas B. Clement, Jack Taunton

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueClinical Journal of Sport Medicine · 2000
Typearticle
Languageen
FieldMedicine
TopicExercise and Physiological Responses
Canadian institutionsUniversity of British Columbia
Fundersnot available
KeywordsMedicineDelayed onset muscle sorenessIsometric exerciseCreatine kinaseVisual analogue scalePlaceboCrossover studyEccentricmyalgiaPhysical therapyAnesthesiaMuscle damageInternal medicinePathology

Abstract

fetched live from OpenAlex

OBJECTIVE: To assess the hypothesis that Farabloc, a fabric with electromagnetic shielding properties, would attenuate the symptoms, signs, and muscular strength deficit secondary to delayed-onset muscle soreness (DOMS) induced by two exposures to eccentric exercise in humans. DESIGN: Randomized, single-blind, placebo-controlled, crossover trial with two testing stages of 5 days duration separated by a washout period of more than 8 weeks. SETTING: University-based sports medicine center. PARTICIPANTS: Twenty volunteers equally representing untrained male and female subjects. INTERVENTIONS: 20 sets of 10 repetitions of single-leg eccentric knee extensions for 37 minutes with the Biodex dynamometer set at 30 degrees per second were performed on the first day of stage one and stage two to induce DOMS in the quadriceps muscle. Double layers of fabric, either Farabloc or placebo, were wrapped around the thigh of each participant during each stage for 5 days. MAIN OUTCOME MEASURES: Perception of muscle pain, as measured by a visual analog scale (VAS), and strength, as measured by knee extensor torque (EST) with the Biodex dynamometer, were evaluated at 0, 24, 48, 72, and 96 hours. Serum inflammatory markers of muscle damage, including malondialdehyde. creatine phosphokinase, myoglobin, leukocytes, and neutrophils, were assayed at 0, 2, 6, 24, and 48 hours. RESULTS: Repeated-measures analysis of variance was carried out for each of the seven variables to assess differences for fabric, order of treatment, time, and all combinations. Results of VAS and EST and levels of malondialdehyde, creatine phosphokinase, myoglobin, leukocytes, and neutrophils all showed a highly significant effect of Farabloc compared with placebo. This analysis shows that the order of Farabloc or placebo fabric use in stage I and 2 produces different results. This may be caused by a learning effect, but did not alter the overall influence of Farabloc. CONCLUSION: The data indicate that double layers of Farabloc fabric wrapped around the thigh reduces pain and strength loss and serum levels of malondialdehyde, creatine phosphokinase, myoglobin, leukocytes, and neutrophils when untrained human subjects are exposed to eccentric exercise to produce DOMS in the quadriceps. Farabloc shields high-frequency electromagnetic fields, although the results do not indicate how these changes are mediated. Further research is needed to determine the mechanism.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.002
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.710
Threshold uncertainty score0.693

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.046
GPT teacher head0.390
Teacher spread0.344 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it