MétaCan
Menu
Back to cohort
Record W2135157480 · doi:10.1117/1.3583581

Rhodamine 800 as a near-infrared fluorescent deposition flow tracer in rodent hearts

2011· article· en· W2135157480 on OpenAlexafffund
Garret Munch, Scott McKay, Eugene Gussakovsky, Bozena Kuzio, V.V. Kupriyanov, Olga Jilkina

Bibliographic record

VenueJournal of Biomedical Optics · 2011
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsNational Research Council CanadaNational Research Council Institute for BiodiagnosticsUniversity of Manitoba
FundersManitoba Health Research Council
KeywordsAbsorbanceFluorescencePerfusionRhodamineRhodamine BIndocyanine greenChemistryTRACERFluorescence-lifetime imaging microscopyPathologyInternal medicineMedicineChromatographyBiochemistry

Abstract

fetched live from OpenAlex

We investigated the use of a near-infrared (NIR) fluorescent dye, Rhodamine 800 (Rhod800, λ(exc) = 693 nm, λ(em) > 720 nm) as a flow-dependent molecular tracer for NIR spectroscopy and high-resolution cardiac imaging. Rhod800 accumulates in isolated mitochondria in proportion to the mitochondrial membrane potential (ΔΨ). However, in the intact myocardium, Rhod800 binding is ΔΨ-independent. Rat hearts were perfused in a Langendorff mode with Krebs-Henseleit buffer containing 45-nM Rhod800 at normal (100%), increased (150%), or reduced (50%) baseline coronary flow (CF) per gram, for 30 to 60 min. In a different group of hearts, the left anterior descending artery (LAD) was occluded prior to Rhod800 infusion to create a flow deficit area. Rhod800 deposition was analyzed by: 1. absorbance spectroscopy kinetics in the Rhod800-perfused hearts, 2. Rhod800 absorbance and fluorescence imaging in the short-axis heart slices, and 3. dynamic epicardial/subepicardial fluorescence imaging of Rhod800 in KCl-arrested hearts, with a spatial resolution of ∼ 200 μm. Rhod800 deposition was proportional to the perfusate volume (CF and perfusion time) and there was no Rhod800 loss during the washout period. In the LAD-ligated hearts, Rhod800 fluorescence was missing from the no-flow, LAD-dependent endocardial and epicardial/subepicardial area. We concluded that Rhod800 can be used as a deposition flow tracer for dynamic cardiac imaging.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0010.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.307
Teacher spread0.282 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations4
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Biomedical OpticsSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207