MétaCan
Menu
Back to cohort
Record W2135983724 · doi:10.1115/1.4006576

Experimental Study to Characterize the Performance of Combined Photovoltaic/Thermal Air Collectors

2012· article· en· W2135983724 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueJournal of Solar Energy Engineering · 2012
Typearticle
Languageen
FieldEnergy
TopicSolar Thermal and Photovoltaic Systems
Canadian institutionsPolytechnique MontréalNatural Resources Canada
FundersNatural Resources Canada
KeywordsPhotovoltaic systemThermalOpen-circuit voltageEnvironmental scienceMaterials scienceNuclear engineeringPhotovoltaic thermal hybrid solar collectorVoltageVolumetric flow rateAutomotive engineeringMechanicsThermodynamicsElectrical engineeringEngineeringPhysics

Abstract

fetched live from OpenAlex

Combined photovoltaic/thermal (PV/T) collectors show great potential for reaching the objective of net-zero energy consumption in buildings, but the number of products on the market is still very limited. One of the reasons for the slow market uptake of PV/T collectors is the absence of standardized methods to characterize their performance. Performance characterization is a challenge for PV/T collectors because of the interaction between the thermal and electrical yield. This study addresses this particular issue for PV/T air collectors used in either closed-loop or open-loop configurations. In particular, it presents the potential of the equivalent cell temperature method to determine the temperature of the PV cells in a PV/T air collector and validates models to predict the thermal performance and cell temperature for this particular type of solar collector. Indoor and outdoor experimental tests were performed on two c-Si unglazed PV/T modules. The indoor part of this procedure provided the thermal diode voltage factor and the open-circuit voltage temperature coefficient, two parameters that are essential in the calculation of the equivalent cell temperature. The outdoor procedure consisted of acquiring simultaneous electrical and thermal measurements at various inlet temperatures and flowrates. For the collector used in a closed-loop configuration, thermal efficiency models using the fluid inlet, outlet, or average temperature in the calculation of the reduced temperature provided similar results. For an open-loop configuration, a thermal efficiency model as a function of the fluid outlet flowrate was found to be more appropriate. Using selection of variable methods, it was found that a multiple linear regression model using the fluid inlet temperature, the irradiance, and the fluid outlet temperature as predictive variables could be used to estimate both the PV module back surface average temperature and the equivalent cell temperature. When using the PV temperature predicted by these models in the electrical efficiency model, both PV temperatures showed similar performance. In collectors where the PV back surface temperature is not accessible for temperature sensors mounting, the equivalent cell temperature provides a valuable alternative to be used as the PV temperature. The PV/T collector thermal and electrical performance in either closed-loop or open-loop configurations was found to be encapsulated with a series of five-plots.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.041
Threshold uncertainty score0.672

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.012
GPT teacher head0.209
Teacher spread0.197 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it