MétaCan
Menu
← all works

Paradoxical Low-Flow, Low-Gradient Severe Aortic Stenosis Despite Preserved Ejection Fraction Is Associated With Higher Afterload and Reduced Survival

2007· article· en· 951 citations· W2137038354 on OpenAlex· 10.1161/circulationaha.106.668681

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.
Canadian funderA Canadian agency funded it. The work may carry no Canadian affiliation at all.

Full frame distilled prediction

Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

Candidate categories
none
Consensus categories
none
Domain
Candidate signal: noneConsensus signal: none
Study design
Candidate signal: ObservationalConsensus signal: Observational
Genre
Candidate signal: EmpiricalConsensus signal: Empirical
Teacher disagreement score
0.003
Threshold uncertainty score
0.629
Validation status
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.018
GPT teacher head0.293
Teacher spread
0.275 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

BACKGROUND: Recent studies and current clinical observations suggest that some patients with severe aortic stenosis on the basis of aortic valve area may paradoxically have a relatively low gradient despite the presence of a preserved left ventricular (LV) ejection fraction. The objective of the present study was to document the prevalence, potential mechanisms, and clinical relevance of this phenomenon. METHODS AND RESULTS: We retrospectively studied the clinical and Doppler echocardiographic data of 512 consecutive patients with severe aortic stenosis (indexed aortic valve area < or = 0.6 cm2 x m(-2)) and preserved LV ejection fraction (> or = 50%). Of these patients, 331 (65%) had normal LV flow output defined as a stroke volume index > 35 mL x m2, and 181 (35%) had paradoxically low-flow output defined as stroke volume index < or = 35 mL x m(-2). When compared with normal flow patients, low-flow patients had a higher prevalence of female gender (P<0.05), a lower transvalvular gradient (32+/-17 versus 40+/-15 mm Hg; P<0.001), a lower LV diastolic volume index (52+/-12 versus 59+/-13 mL x m(-2); P<0.001), lower LV ejection fraction (62+/-8% versus 68+/-7%; P<0.001), a higher level of LV global afterload reflected by a higher valvulo-arterial impedance (5.3+/-1.3 versus 4.1+/-0.7 mm Hg x mL(-1) x m(-2); P<0.001) and a lower overall 3-year survival (76% versus 86%; P=0.006). Only age (hazard ratio, 1.04; 95% CI, 1.01 to 1.08; P=0.025), valvulo-arterial impedance > 5.5 mm Hg x mL(-1) x m(-2) (hazard ratio, 2.6; 95% CI, 1.2 to 5.7; P=0.017), and medical treatment (hazard ratio, 3.3; 95% CI, 1.8 to 6.7; P=0.0003) were independently associated with increased mortality. CONCLUSION: Patients with severe aortic stenosis may have low transvalvular flow and low gradients despite normal LV ejection fraction. A comprehensive evaluation shows that this pattern is in fact consistent with a more advanced stage of the disease and has a poorer prognosis. Such findings are clinically relevant because this condition may often be misdiagnosed, which leads to a neglect and/or an underestimation of symptoms and an inappropriate delay of aortic valve replacement surgery.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
Circulation
Topic
Cardiac Valve Diseases and Treatments
Field
Medicine
Canadian institutions
Université Laval
Funders
Canadian Institutes of Health Research
Keywords
MedicineCardiologyAfterloadInternal medicineEjection fractionStroke volumeStenosisAortic valve stenosisHazard ratioHemodynamicsHeart failureConfidence interval
Has abstract in OpenAlex
yes