MétaCan
Menu
Back to cohort
Record W2137369542 · doi:10.1161/jaha.115.001983

Very Low Ventricular Pacing Rates Can Be Achieved Safely in a Heterogeneous Pacemaker Population and Provide Clinical Benefits: The CANadian Multi‐Centre Randomised Study‐Spontaneous AtrioVEntricular Conduction pReservation (CAN‐SAVE R) Trial

2015· article· en· W2137369542 on OpenAlexaffabout
Bernard Thibault, Anique Ducharme, Adrián Baranchuk, Marc Dubuc, Katia Dyrda, Peter G. Guerra, Laurent Macle, Blandine Mondésert, Léna Rivard, Denis Roy, Mario Talajic, Jason G. Andrade, R. Nitzsché, Paul Khairy

Bibliographic record

VenueJournal of the American Heart Association · 2015
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsKingston General HospitalUniversité de MontréalMontreal Heart Institute
Fundersnot available
KeywordsMedicineInterquartile rangeCardiologyAtrial fibrillationInternal medicinePopulationSAFERRandomized controlled trialAnesthesia

Abstract

fetched live from OpenAlex

BACKGROUND: It is well recognized that right ventricular apical pacing can have deleterious effects on ventricular function. We performed a head-to-head comparison of the SafeR pacing algorithm versus DDD pacing with a long atrioventricular delay in a heterogeneous population of patients with dual-chamber pacemakers. METHODS AND RESULTS: In a multicenter prospective double-blinded randomized trial conducted at 10 centers in Canada, 373 patients, age 71±11 years, with indications for dual chamber DC pacemakers were randomized 1:1 to SafeR or DDD pacing with a long atrioventricular delay (250 ms). The primary objective was twofold: (1) reduction in the proportion of ventricular paced beats at 1 year; and (2) impact on atrial fibrillation burden at 3 years, defined as the ratio between cumulative duration of mode-switches divided by follow-up time. Statistical significance of both co-primary end points was required for the trial to be considered positive. At 1 year of follow-up, the median proportion of ventricular-paced beats was 4.0% with DDD versus 0% with SafeR (P<0.001). At 3 years of follow-up, the atrial fibrillation burden was not significantly reduced with SafeR versus DDD (median 0.00%, interquartile range [0.00% to 0.23%] versus median 0.01%, interquartile range [0.00% to 0.44%], respectively, P=0.178]), despite a persistent reduction in the median proportion of ventricular-paced beats (10% with DDD compared to 0% with SafeR). CONCLUSIONS: A ventricular-paced rate <1% was safely achieved with SafeR in a population with a wide spectrum of indications for dual-chamber pacing. However, the lower percentage of ventricular pacing did not translate into a significant reduction in atrial fibrillation burden. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov/ Unique identifier: NCT01219621.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.037
Threshold uncertainty score0.073

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0030.003
Meta-epidemiology (narrow)0.0020.000
Meta-epidemiology (broad)0.0020.002
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0010.000
Research integrity0.0010.002
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.052
GPT teacher head0.328
Teacher spread0.276 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designRandomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2015
Admission routes2
Has abstractyes

Explore more

Same venueJournal of the American Heart AssociationSame topicCardiac pacing and defibrillation studiesFrench-language works237,207