MétaCan
Menu
Back to cohort
Record W2137534456

Effect of reduced exposure times on the microhardness of 10 resin composites cured by high-power LED and QTH curing lights.

2006· article· en· W2137534456 on OpenAlexaff
Corey A Felix, Richard Bengt Price, Pantelis Andreou

Bibliographic record

VenuePubMed · 2006
Typearticle
Languageen
FieldDentistry
TopicDental materials and restorations
Canadian institutionsDalhousie University
Fundersnot available
KeywordsMaterials scienceKnoop hardness testComposite materialCuring (chemistry)Indentation hardnessIrradianceHalogen lampLight-emitting diodeIrradiationLight guideBlue lightLight sourceOpticsOptoelectronics
DOInot available

Abstract

fetched live from OpenAlex

PURPOSE: To compare the effect of reduced exposure times on the microhardness of resin composites cured with a "second-generation" light-emitting diode (LED) curing light and a quartz-tungsten-halogen (QTH) curing light. METHODS: Ten composites were cured with a LED curing light for 50% of the manufacturers" recommended exposure time or a QTH light at the high power setting for 50% of the recommended time or on the medium power setting for 100% of the recommended time. The composites were packed into Class I preparations in extracted human molar teeth and cured at distances of 2 or 9 mm from the light guide. The moulds were separated, and the Knoop microhardness of the composites was measured down to 3.5 mm from the surface. RESULTS: The LED light delivered the greatest irradiance at 0 and 2 mm, whereas the QTH light on the standard (high power) setting delivered the highest irradiance at 9 mm. According to distribution-free multiple comparisons of the hardness values, at 2 mm from the light guide the LED light (50% exposure time) was ranked better than or equivalent to the QTH light on the high power setting (50% exposure time) or on the medium power setting (100% exposure time). At 9 mm, the LED light was ranked better than or equivalent to the QTH light (both settings) to a depth of 1.5 mm, beyond which composites irradiated by the LED light were softer (p < 0.01). At both distances, the QTH light operated on the high power setting for 50% of the recommended exposure time produced composites that were as hard as when they were exposed on the medium power setting for 100% of the recommended exposure time. CONCLUSIONS: The ability to reduce exposure times with high-power LED or QTH lights may improve clinical time management.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.003
Threshold uncertainty score0.011

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0030.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.004
GPT teacher head0.201
Teacher spread0.197 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations23
Published2006
Admission routes1
Has abstractyes

Explore more

Same venuePubMedSame topicDental materials and restorationsFrench-language works237,207