MétaCan
Menu
← all works

Anticoagulation of Pregnant Women With Mechanical Heart Valves

2000· review· en· 749 citations· W2138444098 on OpenAlex· 10.1001/archinte.160.2.191

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.

Full frame distilled prediction

Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

Candidate categories
Meta-epidemiology (narrow)
Consensus categories
none
Domain
Candidate signal: noneConsensus signal: none
Study design
Candidate signal: Other designConsensus signal: none
Genre
Candidate signal: ReviewConsensus signal: Review
Teacher disagreement score
0.970
Threshold uncertainty score
1.000
Validation status
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0040.001
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.026
GPT teacher head0.329
Teacher spread
0.303 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

BACKGROUND: The management of women with prosthetic heart valves during pregnancy poses a particular challenge as there are no available controlled clinical trials to provide guidelines for effective antithrombotic therapy. Oral anticoagulants such as warfarin sodium cause fetal embryopathy; subcutaneous administration of heparin sodium has been reported to be ineffective in preventing thromboembolic complications. OBJECTIVE: To identify the risks of maternal and fetal complications in women with mechanical heart valves treated with different anticoagulation regimens during pregnancy. METHODS: We performed a systematic review of the literature to determine pooled estimates of maternal and fetal risks associated with the 3 commonly used approaches: (1) oral anticoagulants (OA) throughout pregnancy, (2) replacing OA with heparin in the first trimester (from 6-12 weeks' gestation), and (3) heparin use throughout pregnancy. Fetal outcomes included spontaneous abortions and fetopathic effects, and maternal outcomes were major bleeding, thromboembolic complications, and death. RESULTS: The use of OA throughout pregnancy is associated with warfarin embryopathy in 6.4% (95% confidence interval [CI], 4.6%-8.9%) of livebirths. The substitution of heparin at or prior to 6 weeks, and continued until 12 weeks, eliminated this risk. Overall risks for fetal wastage (spontaneous abortion, stillbirths, and neonatal deaths) were similar in women treated with OA throughout, compared with women treated with heparin in the first trimester. Maternal mortality was 2.9% (95% CI, 1.9%-4.2%). Maj or bleeding events occurred in 2.5% (95% CI, 1.7%-3.5%) of all pregnancies, most at the time of delivery. The regimen associated with the lowest risk of valve thrombosis (3.9%; 95% CI, 2.9-5.9%) was the use of OA throughout; using heparin only between 6 and 12 weeks' gestation was associated with an increased risk of valve thrombosis (9.2%; 95% CI, 5.9%-13.9%). CONCLUSIONS: Thromboembolic prophylaxis of women with mechanical heart valves during pregnancy is best achieved with OA; however, this increases the risk of fetal embryopathy. Substituting OA with heparin between 6 and 12 weeks reduces the risk of fetopathic effects, but with an increased risk of thromboembolic complications. The use of low-dose heparin is definitely inadequate; the use of adjusted-dose heparin warrants aggressive monitoring and appropriate dose adjustment. Large prospective trials to determine the best regimen for these women are needed.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
Archives of Internal Medicine
Topic
Cardiovascular Issues in Pregnancy
Field
Medicine
Canadian institutions
Women's College Hospital
Funders
not available
Keywords
MedicinePregnancyAbortionObstetricsWarfarinHeparinRegimenGestationFetusSurgeryInternal medicineAtrial fibrillation
Has abstract in OpenAlex
yes