Cardiac Resynchronization Therapy in Patients With Permanent Atrial Fibrillation
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
BACKGROUND: Cardiac resynchronization (CRT) prolongs survival in patients with systolic heart failure and QRS prolongation. However, most trials excluded patients with permanent atrial fibrillation. METHODS AND RESULTS: The Resynchronization for Ambulatory Heart Failure Trial (RAFT) randomized patients to an implantable cardioverter defibrillator (ICD) or ICD+CRT, stratified by the presence of permanent atrial fibrillation. Patients with permanent atrial fibrillation were randomized to CRT-ICD (n=114) or ICD (n=115). Patients receiving a CRT-ICD were similar to those receiving an ICD: age (71.6±7.3 versus 70.4±7.7 years), left ventricular ejection fraction (22.9±5.3% versus 22.3±5.1%), and QRS duration (151.0±23.6 versus 153.4±24.7 ms). There was no difference in the primary outcome of death or heart failure hospitalization between those assigned to CRT-ICD versus ICD (hazard ratio, 0.96; 95% CI, 0.65-1.41; P=0.82). Cardiovascular death was similar between treatment arms (hazard ratio, 0.97; 95% CI, 0.55-1.71; P=0.91); however, there was a trend for fewer heart failure hospitalizations with CRT-ICD (hazard ratio, 0.58; 95% CI, 0.38-1.01; P=0.052). The change in 6-minute hall walk duration between baseline and 12 months was not different between treatment arms (CRT-ICD: 19±84 m versus ICD: 16±76 m; P=0.88). Patients treated with CRT-ICD showed a trend for a greater improvement in Minnesota Living with Heart Failure score between baseline and 6 months (CRT-ICD: 41±21 to 31±21; ICD: 33±20 to 28±20; P=0.057). CONCLUSIONS: Patients with permanent atrial fibrillation who are otherwise CRT candidates appear to gain minimal benefit from CRT-ICD compared with a standard ICD.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it