MétaCan
Menu
← all works

Standardization of Methods for Fluence (UV Dose) Determination in Bench-Scale UV Experiments

2003· article· en· 1,210 citations· W2139303634 on OpenAlex· 10.1061/(asce)0733-9372(2003)129:3(209)

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.

Full frame distilled prediction

Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

Candidate categories
none
Consensus categories
none
Domain
Candidate signal: noneConsensus signal: none
Study design
Candidate signal: Bench or experimentalConsensus signal: Bench or experimental
Genre
Candidate signal: EmpiricalConsensus signal: Empirical
Teacher disagreement score
0.185
Threshold uncertainty score
0.383
Validation status
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.009
GPT teacher head0.275
Teacher spread
0.266 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

Ultraviolet (UV) disinfection is now an accepted technology for inactivation of a variety of waterborne pathogens in wastewater and drinking water. However, the techniques used in much of the previous research aimed at providing information on UV effectiveness have not yet been standardized. Thus in many peer reviewed published literature, it is not clear how the UV irradiations were carried out, nor how the average fluence (or UV dose) given to the microorganisms has been determined. A detailed protocol for the determination of the fluence (UV dose) in a bench scale UV apparatus containing UV lamps emitting either monochromatic or broadband UV light was developed. This protocol includes specifications for the construction of a bench scale UV testing apparatus, methods for determination of the average irradiance in the water, details on UV radiometry, and considerations for microbiological testing. Use of this protocol will aid in standardization of bench scale UV testing and provide increased confidence in data generated during such testing.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
Journal of Environmental Engineering
Topic
Water Treatment and Disinfection
Field
Environmental Science
Canadian institutions
Alberta Environment and Protected Areas
Funders
not available
Keywords
UltravioletProtocol (science)Environmental scienceStandardizationFluenceMaterials scienceIrradianceProcess engineeringComputer scienceOpticsOptoelectronicsPhysicsMedicineEngineering
Has abstract in OpenAlex
yes