MétaCan
Menu
Back to cohort
Record W2139328911 · doi:10.13052/jge1904-4720.422

Design and Perfromance Characteristics of a Portable Solar-Driven Thermoelectric Heat Pump under Thunder Bay Extreme Cold Conditions in Northwestern Ontario, Canada

2014· article· en· W2139328911 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.
aboutThe title or abstract carries a Canadian signal from the geographic lexicon.

Bibliographic record

VenueJournal of Green Engineering · 2014
Typearticle
Languageen
FieldMaterials Science
TopicAdvanced Thermoelectric Materials and Devices
Canadian institutionsLakehead University
FundersNatural Sciences and Engineering Research Council of CanadaGoldcorp
KeywordsThunderHeat pumpThermoelectric effectRenewable energyThermoelectric coolingPhotovoltaic systemEnvironmental scienceThermoelectric generatorNuclear engineeringSolar energyAutomotive engineeringMechanical engineeringProcess engineeringEngineeringMaterials scienceElectrical engineeringMeteorologyThermodynamicsHeat exchangerPhysics

Abstract

fetched live from OpenAlex

Renewable & alternative non-conventional green energy technologies used for heat-pumping applications have shown real merits and received renewed interest in recent years especially in small-scale portable heating applications. Solar-driven thermoelectric heat pumping is one of these innovative technologies. In this paper, a thermoelectric heat pump that utilizes the Peltier effect has been designed, constructed and instrumented for suitable experimentation and characterization under Thunder Bay city extreme cold weather conditions in Canada. The thermoelectric test setup is powered using a renewable solar photovoltaic system and tested under different operating conditions. It was found that the PV-powered thermoelectric heat pump system has shown an acceptable performance with COP ranging from 0.98-1.22. Typical results showed that the average heat pumping power for the system was 72.1 W when the system was operated at an ambient temperature of -17 o C with an inside system temperature increased from approximately -5 o C to 25 o C.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.627
Threshold uncertainty score0.852

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.192
Teacher spread0.181 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it