MétaCan
Menu
Back to cohort
Record W2140285069 · doi:10.1016/j.mayocp.2013.11.016

Contamination of Stethoscopes and Physicians' Hands After a Physical Examination

2014· article· en· W2140285069 on OpenAlexfundno aff
Yves Longtin, Alexis Schneider, Clément Tschopp, Gesuèle Renzi, Angèle Gayet‐Ageron, Jacques Schrenzel, Didier Pittet

Bibliographic record

VenueMayo Clinic Proceedings · 2014
Typearticle
Languageen
FieldMedicine
TopicInfection Control in Healthcare
Canadian institutionsnot available
FundersHôpitaux Universitaires de GenèveSchweizerischer Nationalfonds zur Förderung der Wissenschaftlichen ForschungMcGill UniversityJewish General HospitalUniversité de GenèveInfectious Diseases Society of AmericaNational Science Foundation
KeywordsMedicineStethoscopeContaminationPhysical examinationMedical emergencySurgeryRadiology

Abstract

fetched live from OpenAlex

OBJECTIVES: To compare the contamination level of physicians' hands and stethoscopes and to explore the risk of cross-transmission of microorganisms through the use of stethoscopes. PATIENTS AND METHODS: We conducted a structured prospective study between January 1, 2009, and May 31, 2009, involving 83 inpatients at a Swiss university teaching hospital. After a standardized physical examination, 4 regions of the physician's gloved or ungloved dominant hand and 2 sections of the stethoscopes were pressed onto selective and nonselective media; 489 surfaces were sampled. Total aerobic colony counts (ACCs) and total methicillin-resistant Staphylococcus aureus (MRSA) colony-forming unit (CFU) counts were assessed. RESULTS: Median total ACCs (interquartile range) for fingertips, thenar eminence, hypothenar eminence, hand dorsum, stethoscope diaphragm, and tube were 467, 37, 34, 8, 89, and 18, respectively. The contamination level of the diaphragm was lower than the contamination level of the fingertips (P<.001) but higher than the contamination level of the thenar eminence (P=.004). The MRSA contamination level of the diaphragm was higher than the MRSA contamination level of the thenar eminence (7 CFUs/25 cm(2) vs 4 CFUs/25 cm(2); P=.004). The correlation analysis for both total ACCs and MRSA CFU counts revealed that the contamination level of the diaphragm was associated with the contamination level of the fingertips (Spearman's rank correlation coefficient, ρ=0.80; P<.001 and ρ=0.76; P<.001, respectively). Similarly, the contamination level of the stethoscope tube increased with the increase in the contamination level of the fingertips for both total ACCs and MRSA CFU counts (ρ=0.56; P<.001 and ρ=.59; P<.001, respectively). CONCLUSION: These results suggest that the contamination level of the stethoscope is substantial after a single physical examination and comparable to the contamination of parts of the physician's dominant hand.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.014
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.007
Threshold uncertainty score0.014

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.014
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0010.001
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.002
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.317
Teacher spread0.303 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations123
Published2014
Admission routes1
Has abstractno

Explore more

Same venueMayo Clinic ProceedingsSame topicInfection Control in HealthcareFrench-language works237,207