Preload-independent mechanisms contribute to increased stroke volume following large volume saline infusion in normal volunteers: a prospective interventional study

2004· article· en· W2140389030 on OpenAlexaff
Anand Kumar, Ramon Añel, Eugene Bunnell, Sergio Zanotti, Kalim Habet, Cameron Haery, Stephanie Marshall, Mary Cheang, Alex Neumann, Amjad Ali, Clifford J. Kavinsky, Joseph E. Parrillo

Bibliographic record

VenueCritical Care · 2004
Typearticle
Languageen
FieldMedicine
TopicHemodynamic Monitoring and Therapy
Canadian institutionsUniversity of Manitoba
Fundersnot available
KeywordsMedicinePreloadStroke volumeSalineStroke (engine)Volume (thermodynamics)Prospective cohort studyAnesthesiaEmergency medicineIntensive care medicineHemodynamicsInternal medicineHeart rateBlood pressure

Abstract

fetched live from OpenAlex

INTRODUCTION: Resuscitation with saline is a standard initial response to hypotension or shock of almost any cause. Saline resuscitation is thought to generate an increase in cardiac output through a preload-dependent (increased end-diastolic volume) augmentation of stroke volume. We sought to confirm this to be the mechanism by which high-volume saline administration (comparable to that used in resuscitation of shock) results in improved cardiac output in normal healthy volunteers. METHODS: Using a standardized protocol, 24 healthy male (group 1) and 12 healthy mixed sex (group 2) volunteers were infused with 3 l normal (0.9%) saline over 3 hours in a prospective interventional study. Individuals were studied at baseline and following volume infusion using volumetric echocardiography (group 1) or a combination of pulmonary artery catheterization and radionuclide cineangiography (group 2). RESULTS: Saline infusion resulted in minor effects on heart rate and arterial pressures. Stroke volume index increased significantly (by approximately 15-25%; P < 0.0001). Biventricular end-diastolic volumes were only inconsistently increased, whereas end-systolic volumes decreased almost uniformly. Decreased end-systolic volume contributed as much as 40-90% to the stroke volume index response. Indices of ventricular contractility including ejection fraction, ventricular stroke work and peak systolic pressure/end-systolic volume index ratio all increased significantly (minimum P < 0.01). CONCLUSION: The increase in stroke volume associated with high-volume saline infusion into normal individuals is not only mediated by an increase in end-diastolic volume, as standard teaching suggests, but also involves a consistent and substantial decrease in end-systolic volumes and increases in basic indices of cardiac contractility. This phenomenon may be consistent with either an increase in biventricular contractility or a decrease in afterload.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Non-randomized trial · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.006

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.002
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.010
GPT teacher head0.311
Teacher spread0.302 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designNon-randomized trial
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations54
Published2004
Admission routes1
Has abstractyes

Explore more

Same venueCritical CareSame topicHemodynamic Monitoring and TherapyFrench-language works237,207