MétaCan
Menu
Back to cohort
Record W2140921498 · doi:10.1039/c4an02321h

A HPLC-SRM-MS based method for the detection and quantification of methotrexate in urine at doses used in clinical practice for patients with rheumatological disease: a potential measure of adherence

2015· article· en· W2140921498 on OpenAlexaff
James Bluett, Isabel Riba‐Garcia, Katherine A. Hollywood, Suzanne Verstappen, Anne Barton, Richard D. Unwin

Bibliographic record

VenueThe Analyst · 2015
Typearticle
Languageen
FieldMedicine
TopicRheumatoid Arthritis Research and Therapies
Canadian institutionsHealth Sciences Centre
FundersMedical Research Council
KeywordsMedicineUrineMethotrexateClinical PracticeHigh-performance liquid chromatographyChromatographyMeasure (data warehouse)PharmacologyInternal medicineChemistryComputer scienceData miningPhysical therapy

Abstract

fetched live from OpenAlex

Rheumatoid arthritis (RA) is a common autoimmune disease that causes significant disability and reduced life expectancy. The folate antagonist methotrexate (MTX) is first-line therapy for RA when used weekly at low doses (5-25 mg). However, the true rate of adherence to MTX is uncertain. This is in part due to the different methods of measurement of adherence employed with no biochemical test currently available to determine adherence to low dose MTX. Common methods of MTX measurement include immunoassays in patients with high dose therapy, but these assays cross-react with MTX metabolites and lack the sensitivity required to measure adherence to low dose MTX. HPLC-SRM-MS (selected reaction monitoring-mass spectrometry) has several theoretical advantages over immunoassays with improved specificity, minimal cross-reaction and higher sensitivity. The aim of this study was to develop an assay to measure MTX and its major metabolite 7-OH-MTX in urine as a tool to monitor adherence to low dose MTX in clinic. As a proof of concept, urine samples from 4 participants with RA were measured after directly observed therapy. The assay showed improved sensitivity compared to that reported by immunoassays, with low carryover and high within-run precision. In participant samples, MTX was measurable in the urine for up to 105 hours after administration and 7-OH-MTX was detectable up to 98 hours after administration, suggesting that this assay is suitable for the measurement of adherence to therapy. The assay requires minimal sample preparation and can be adopted by other laboratories with minimal study set up.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.004
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Methods · Consensus signal: none
Teacher disagreement score0.002
Threshold uncertainty score0.013

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.004
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0020.002
Science and technology studies0.0010.001
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.002

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.077
GPT teacher head0.393
Teacher spread0.316 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreMethods

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2015
Admission routes1
Has abstractyes

Explore more

Same venueThe AnalystSame topicRheumatoid Arthritis Research and TherapiesFrench-language works237,207