MétaCan
Menu
← all works

Autonomous Load Sharing of Voltage Source Converters

2005· article· en· 290 citations· W2141557852 on OpenAlex· 10.1109/tpwrd.2004.838638

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian affiliationAn author listed a Canadian institution. This is the only route the usual frame has.

Full frame distilled prediction

Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

Candidate categories
none
Consensus categories
none
Domain
Candidate signal: noneConsensus signal: none
Study design
Candidate signal: Simulation or modelingConsensus signal: Simulation or modeling
Genre
Candidate signal: EmpiricalConsensus signal: none
Teacher disagreement score
0.921
Threshold uncertainty score
0.624
Validation status
machine_predicted_unvalidated · codex-gemma-dda1882f352a

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.005
GPT teacher head0.175
Teacher spread
0.170 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

An autonomous load-sharing technique for parallel connected three-phase voltage source converters is presented. An improved power-frequency droop scheme computes and sets the phase angle of the voltage source converter (VSC) directly to yield more rapid real power sharing without sacrificing frequency regulation. Reactive power sharing in the presence of a mismatch between the VSC output interface inductors is achieved by having each VSC regulate the high side voltage with a drooped voltage reference. Dynamics of the reactive power control can be tuned without interfering with steady-state reactive power sharing. Simulation results that validate the proposed technique are also provided.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
IEEE Transactions on Power Delivery
Topic
Microgrid Control and Optimization
Field
Engineering
Canadian institutions
University of Toronto
Funders
not available
Keywords
Voltage droopVoltage sourceAC powerConvertersVoltage regulationVoltage optimisationVoltagePower factorControl theory (sociology)Electronic engineeringPower (physics)InductorSwitched-mode power supplyThree-phaseComputer scienceEngineeringElectrical engineeringControl (management)Physics
Has abstract in OpenAlex
yes