MétaCan
Menu
Back to cohort
Record W2141780657 · doi:10.1186/1476-7120-1-9

Early diastolic filling dynamics in diastolic dysfunction

2003· article· en· W2141780657 on OpenAlexaff
Gerard King, Jerome B. Foley, Faisal Al-Mane, Peter Crean, Michael J. Walsh

Bibliographic record

VenueCardiovascular Ultrasound · 2003
Typearticle
Languageen
FieldMedicine
TopicCardiovascular Function and Risk Factors
Canadian institutionsTrinity College
Fundersnot available
KeywordsDiastoleInternal medicineCardiologyMedicineAngiologyMitral valveBlood flowBlood pressure

Abstract

fetched live from OpenAlex

BACKGROUND: The aim of the study was to determine the relationship between the rate of peak early mitral inflow velocity and the peak early diastolic mitral annular tissue velocities in normal controls and to compare them with subjects with diastolic dysfunction. METHODS: The relationship between early passive diastolic transmitral flow and peak early mitral annular velocity in the normal and in diastolic dysfunction was studied. Two groups comprising 22 normal controls and 25 patients with diastolic dysfunction were studied. RESULTS: Compared with the normal group, those with diastolic dysfunction had a lower E/A ratio (0.7 +/- 0.2 vs. 1.9 +/- 0.5, p < 0.001), a higher time-velocity integral of the atrial component (11.7 +/- 3.2 cm vs. 5.5 +/- 2.1 cm, p < 0.0001), a longer isovolumic relaxation time 73 +/- 12 ms vs. 94 +/- 6 ms, p < 0.01 and a lower rate of acceleration of blood across the mitral valve (549.2 +/- 151.9 cm/sec2 vs. 871 +/- 128.1 cm/sec2, p < 0.001). They also had a lower mitral annular relaxation velocity (Ea) (6.08 +/- 1.6 cm/sec vs 12.8 +/- 0.67 cm/sec, p < 0.001), which was positively correlated to the acceleration of early diastolic filling (R = 0.66), p < 0.05. CONCLUSIONS: This investigation provides information on the acceleration of early diastolic filling and its relationship to mitral annular peak tissue velocity (Ea) recorded by Doppler tissue imaging. It supports not only the premise that recoil is an important mechanism for rapid early diastolic filling but also the existence of an early diastolic mechanism in normal.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.168
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.218
Teacher spread0.207 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations6
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueCardiovascular UltrasoundSame topicCardiovascular Function and Risk FactorsFrench-language works237,207