MétaCan
Menu
Back to cohort
Record W2142263867 · doi:10.1259/bjr/31850970

Evaluation of breast amorphous calcifications by a computer-aided detection system in full-field digital mammography

2012· article· en· W2142263867 on OpenAlexaff
Anabel M. Scaranelo, Riham Eiada, Karina Bukhanov, Pavel Crystal

Bibliographic record

VenueBritish Journal of Radiology · 2012
Typearticle
Languageen
FieldMedicine
TopicDigital Radiography and Breast Imaging
Canadian institutionsUniversity of TorontoUniversity Health NetworkPrincess Margaret Cancer Centre
Fundersnot available
KeywordsMedicineMammographyDigital mammographyRadiologyMalignancyBiopsyBreast cancerCADBreast biopsyPathologyInternal medicineCancer

Abstract

fetched live from OpenAlex

OBJECTIVES: The purpose of this study was to evaluate the performance of a direct computer-aided detection (d-CAD) system integrated with full-field digital mammography (FFDM) in assessment of amorphous calcifications. METHODS: From 1438 consecutive stereotactic-guided biopsies, FFDM images with amorphous calcifications were selected for retrospective evaluation by d-CAD in 122 females (mean age, 56 years; range, 35-84 years). The sensitivity, specificity, accuracy and false-positive rate of the d-CAD system were calculated in the total group of 124 lesions and in the subgroups based on breast density, mammographic lesion distribution and extension. Logistic regression analysis was used to stratify the risk of malignancy by patient risk factors and age. RESULTS: The d-CAD marked all (36/36) breast cancers, 85% (11/13) of the high-risk lesions and 80% (60/75) of benign amorphous calcifications (p<0.01) correctly. The sensitivity, specificity and diagnostic accuracy for the combined malignant and "high-risk" lesions was 96, 80 and 86%, respectively. The likelihood of malignancy was 29%. There was no significant difference between the marking of fatty or dense breasts (p>0.05); however, d-CAD marks showed differences for small (<7 mm) lesions (p=0.02) and clustered calcifications (p=0.03). The false-positive rate of d-CAD was 1.76 marks per full examination. CONCLUSION: The d-CAD system correctly marked all biopsy-proven breast cancers and a large number of biopsy-proven high-risk lesions that presented as amorphous calcifications. Given our 29% likelihood of malignancy, imaging-guided biopsy appears to be a reasonable recommendation in cases of amorphous calcifications marked by d-CAD.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.869
Threshold uncertainty score0.436

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.011
GPT teacher head0.247
Teacher spread0.236 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations15
Published2012
Admission routes1
Has abstractyes

Explore more

Same venueBritish Journal of RadiologySame topicDigital Radiography and Breast ImagingFrench-language works237,207