MétaCan
Menu
Back to cohort
Record W2142278754 · doi:10.1109/tmi.2007.903572

Progress in Multimodality Imaging: Truly Simultaneous Ultrasound and Magnetic Resonance Imaging

2007· article· en· W2142278754 on OpenAlexaff
Laura Curiel, Rajiv Chopra, K. Hynynen

Bibliographic record

VenueIEEE Transactions on Medical Imaging · 2007
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsSunnybrook Health Science Centre
FundersNational Cancer Institute
KeywordsImaging phantomMagnetic resonance imagingMedical imagingModality (human–computer interaction)MultimodalityModalitiesComputer scienceMedical physicsClinical imagingBreast imagingPreclinical imagingArtificial intelligenceComputer visionBiomedical engineeringRadiologyMedicineMammographyIn vivo

Abstract

fetched live from OpenAlex

Multimodality medical imaging takes advantage of the strengths of different imaging modalities to provide a more complete picture of the anatomy under investigation. Many complementary modalities have been combined to form such systems and some are gaining use clinically. One combination that has not been developed, in large part due to technical difficulties, is a combined magnetic resonance (MR) and ultrasound (US) imaging system. Such a system offers the potential to combine the strengths of these modalities in a wide range of diagnostic and therapeutic applications. The goal of this study was to evaluate the feasibility of performing simultaneous multimodality US and MR imaging. An US imaging system capable of operation in a clinical MR imager was developed, and methods to perform simultaneous imaging were investigated. Simultaneous imaging was feasible without any mutual interference by either filtering the transmitted and received US signal, or by synchronizing data acquisition between the two imaging systems. Spatial registration between the two modalities was achieved by using a reference phantom with implanted glass beads in orthogonal planes. Excellent agreement was observed between spatial measurements of an object made with both modalities, and the feasibility of using this system in vivo was demonstrated in a rabbit model. Simultaneous US and MR imaging is achievable, and can provide complementary information about an object under investigation. This demonstration of technical feasibility and the development of a prototype system open up the potential to investigate the promising clinical applications of this combined technology.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.010
Threshold uncertainty score0.053

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0100.006
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0030.003
Science and technology studies0.0000.003
Scholarly communication0.0030.007
Open science0.0020.003
Research integrity0.0030.004
Insufficient payload (model declined to judge)0.0030.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.009
GPT teacher head0.317
Teacher spread0.308 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations60
Published2007
Admission routes1
Has abstractyes

Explore more

Same venueIEEE Transactions on Medical ImagingSame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207