MétaCan
Menu
Back to cohort
Record W2142928875 · doi:10.2106/jbjs.e.00223

Radiographic Methods for the Assessment of Polyethylene Wear After Total Hip Arthroplasty

2005· review· en· W2142928875 on OpenAlexaff
Richard W. McCalden

Bibliographic record

VenueJournal of Bone and Joint Surgery · 2005
Typereview
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsLondon Health Sciences Centre
Fundersnot available
KeywordsRadiographyMedicineTotal hip arthroplastyFemoral headOrthodonticsBiomedical engineeringComputer scienceSurgery

Abstract

fetched live from OpenAlex

All wear-measurement techniques assess femoral head penetration and therefore cannot distinguish between true polyethylene wear and bedding-in. Multiple wear measurements that are made at different time-intervals after bedding-in has occurred are required to determine the true wear rate. Computer-assisted edge-detection techniques offer improved accuracy and precision compared with manual techniques and appear to be ideally suited for the retrospective and prospective examination of large groups of patients with intermediate to long-term radiographic follow-up (more than five years). While radiostereometric analysis offers improved accuracy and precision compared with computer-assisted edge-detection techniques, widescale clinical application is limited because of its relative expense, the required expertise, and the fact that it can only be used in a prospective fashion.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.004
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Review · Consensus signal: Review
Teacher disagreement score0.991
Threshold uncertainty score0.770

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0040.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0040.003
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.060
GPT teacher head0.381
Teacher spread0.321 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreReview

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations113
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Bone and Joint SurgerySame topicOrthopaedic implants and arthroplastyFrench-language works237,207