Structural health monitoring of composite poles using fiber optic sensors
Bibliographic record
Abstract
The development of a fiber optic sensor system for the long-term monitoring of composite glass fiber-reinforced polymer (GFRP) poles is presented Due to aging and substantial usage of these structures, there is a growing interest in developing techniques which evaluate and monitor structural integrity. In the past few years, fiber optic sensor technology has emerged as a promising alternative to conventional methods. Fiber optic sensors can be attached to or embedded in civil structures such as bridges, dams and buildings. They operate by responding to changes in temperature and strain on the structure. One type is called a long gauge fiber optic sensor and it measures the average strain between two points on a structure. Long gauges are interferometric sensors which involve phase matching two optical paths to create a maximum interference pattern at the photodetector. The strain is calculated using the distance in which the reference arm of the interferometer is moved in order to match the optical path lengths.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".