Design of Facemasks for Delivery of Aerosol-Based Medication via Pressurized Metered Dose Inhaler with Valved Holding Chamber: Key Issues that Affect Performance
Bibliographic record
Abstract
Valved holding chambers (VHCs) are widely prescribed for use with pressurized metered dose inhalers (pMDIs) for the treatment of respiratory disease by aerosol therapy. The facemask is the preferred patient interface for use by infants and small children, as well as by geriatric patients, due primarily to poor coordination skills. However, care is required in the design of the facemask-VHC system to optimize the delivery of medication. In particular, it is essential to achieve an effective mask-to-face seal and to minimize the volume of dead space. It is also important to ensure that the fit of the facemask is comfortable to the patient when applied with sufficient force to create a seal. We review each of these design principles and their application in the evolution of a range of VHCs from the same family of devices during the past fifteen years. We also examine the various methods available for evaluating VHC-facemasks as a system, recommending where future work might be directed.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame machine prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.
Distilled classifier scores by category (both heads)
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.001 | 0.001 |
| Meta-epidemiology (narrow) | 0.001 | 0.000 |
| Meta-epidemiology (broad) | 0.001 | 0.001 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.001 | 0.001 |
| Open science | 0.001 | 0.000 |
| Research integrity | 0.001 | 0.001 |
| Insufficient payload (model declined to judge) | 0.001 | 0.002 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".