MétaCan
Menu
Back to cohort
Record W2144428266 · doi:10.2106/jbjs.e.00457

Three Hundred and Twenty-one Periprosthetic Femoral Fractures

2006· article· en· W2144428266 on OpenAlexaboutno aff
Hans Lindahl, Göran Garellick, Hans Regnér, Peter Herberts, Henrik Malchau

Bibliographic record

VenueJournal of Bone and Joint Surgery · 2006
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsnot available
Fundersnot available
KeywordsPeriprostheticMedicineObservational studySurgeryImplantArthroplastyDemographicsIncidence (geometry)RadiographyEtiologyInternal medicine

Abstract

fetched live from OpenAlex

BACKGROUND: The purpose of this study was to determine the demographics, incidence, and results of treatment of periprosthetic fractures in a nationwide observational study. METHODS: In the years 1999 and 2000, 321 periprosthetic fractures were reported to the Swedish National Hip Arthroplasty Register. All of the associated hospital records were collected. At the time of follow-up, the Harris hip score, a health-related quality-of-life measure (the EuroQol-5D [EQ-5D] index), and patient satisfaction were used as outcome measurements. A radiologist performed the radiographic evaluation. RESULTS: Ninety-one patients, with a mean age of 73.8 years, sustained a fracture after one or several revision procedures, and 230 patients, with a mean age of 77.9 years, sustained a fracture after a primary total hip replacement. Minor trauma, including a fall to the floor, and a spontaneous fracture were the main etiologies for the injuries. A high number of patients had a loose stem at the time of the fracture (66% in the primary replacement group and 51% in the revision group). Eighty-eight percent of the fractures were classified as Vancouver type B; however, there was difficulty with preoperative categorization of the fractures radiographically. There was a high failure rate resulting in a low short to mid-term prosthetic survival rate. The sixty-six-month survival rate for the entire fracture group, with reoperation as the end point, was 74.8% +/- 5.0%. One factor associated with fracture risk was implant design. CONCLUSIONS: On the basis of these findings, we believe that high-risk patients should have routine radiographic follow-up. Such a routine could identify a loose implant and make intervention possible before a fracture occurred. Furthermore, we recommend an exploration of the joint to test the stability of the implant in patients with a Vancouver type-B fracture in which the stability of the stem is uncertain.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.004
Threshold uncertainty score0.009

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.001
Meta-epidemiology (broad)0.0000.001
Bibliometrics0.0010.001
Science and technology studies0.0010.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0010.000
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.021
GPT teacher head0.238
Teacher spread0.216 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations338
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Bone and Joint SurgerySame topicOrthopaedic implants and arthroplastyFrench-language works237,207