MétaCan
Menu
Back to cohort
Record W2144906083 · doi:10.1148/radiol.2381041113

Acute Ischemic Stroke: Accuracy of Diffusion-weighted MR Imaging—Effects of<i>b</i>Value and Cerebrospinal Fluid Suppression

2006· article· en· W2144906083 on OpenAlexaff
Philip E. Chen, Jessica Simon, Michael D. Hill, Chul‐Ho Sohn, Peter Dickhoff, William Morrish, Robert J. Sevick, Richard Frayne

Bibliographic record

VenueRadiology · 2006
Typearticle
Languageen
FieldMedicine
TopicAcute Ischemic Stroke Management
Canadian institutionsUniversity of CalgaryFoothills Medical Centre
Fundersnot available
KeywordsMedicineCerebrospinal fluidDiffusion MRIStroke (engine)Ischemic strokeMagnetic resonance imagingValue (mathematics)Acute strokeRadiologyNuclear medicineCardiologyInternal medicineIschemia

Abstract

fetched live from OpenAlex

PURPOSE: To prospectively determine which diffusion-weighted magnetic resonance (MR) imaging technique (ie, conventional diffusion-weighted MR imaging [b = 1000 or 1500 sec/mm2] or fluid-inversion prepared diffusion [FLIPD] MR imaging [b = 1500 sec/mm2]) is most accurate in depicting acute ischemic stroke at 3 T. MATERIALS AND METHODS: The Health Research Ethics Board approved this study; written informed consent was provided by all participants or their surrogate. Diffusion-weighted MR imaging was performed in 75 consecutive patients (43 men, 32 women; mean age, 64.0 years) with acute ischemic stroke. Two experienced neuroradiologists determined the presence of hyperacute stroke lesions at diffusion-weighted MR imaging by locating areas of hyperintensity that corresponded to regions with a decreased diffusion coefficient. These findings were used as the reference standard. Four raters who were blinded to patient history assessed all images and apparent diffusion coefficient maps for the presence of changes that were consistent with acute ischemic stroke. Accuracy, sensitivity, specificity, negative predictive value, positive predictive value, and inter- and intrarater reliability scores were calculated for each technique. RESULTS: Specificity, positive predictive value, and accuracy were not significantly different among the techniques. FLIPD MR images obtained with a b value of 1500 sec/mm2 had decreased sensitivity for acute ischemic stroke (mean, 61.8%; 95% confidence interval [CI]: 55.4%, 67.9%) compared with conventional diffusion-weighted MR images obtained with a b value of either 1000 sec/mm2 (mean, 82.5%; 95% CI: 77.1%, 87.0%) or 1500 sec/mm2 (mean, 84.5%; 95% CI: 79.3%, 88.9%). FLIPD MR images also had decreased negative predictive value (mean, 96.5%; 95% CI: 95.7%, 97.2%) compared with conventional diffusion-weighted MR images obtained with a b value of either 1000 sec/mm2 (mean, 98.4%; 95% CI: 97.8%, 98.8%) or 1500 sec/mm2 (mean, 98.6%; 95% CI: 98.1%, 99.0%). Intra- and interrater reliability scores were generally excellent for all three techniques. CONCLUSION: FLIPD MR images obtained with a b value of 1500 sec/mm2 are less suitable for the detection of acute ischemic stroke owing to a decreased sensitivity and negative predictive value. The performance of the two conventional diffusion-weighted MR imaging techniques (b = 1000 and 1500 sec/mm2) was equivalent.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.065
Threshold uncertainty score0.771

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.003
GPT teacher head0.235
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations24
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueRadiologySame topicAcute Ischemic Stroke ManagementFrench-language works237,207