A Full Bridge Resonant Inverter with Modified Phase Shift Modulation
Bibliographic record
Abstract
A full bridge resonant inverter is proposed as one of the potential building blocks for high frequency ac distributed power supply. Because the load impedance in ac distributed power system is unknown and the input line voltage has wide range of variation, voltage feedback and feed-forward control has to be applied to regulate the output voltage. However with the conventional phase shift modulation (PSM), the phase angle of the inverter output voltage shifts with the line and load perturbation. A modified symmetrical PSM is proposed where triangle waveform is used as carrier signal and the modulation signal is double edge modulated. With this method, the phase angle of the output voltage is independent of the line and load variation. The mechanism is described and analyzed. Performance during steady state and transient shows that the symmetrical PSM inverter is applicable to high frequency ac distributed power system
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.000 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".