MétaCan
Menu
Back to cohort
Record W2145913472 · doi:10.1071/ch02188

New Developments and Applications of Solvent-Free Sampling and Sample Preparation Technologies for the Investigation of Living Systems

2003· article· en· W2145913472 on OpenAlexaff
Janusz Pawliszyn

Bibliographic record

VenueAustralian Journal of Chemistry · 2003
Typearticle
Languageen
FieldChemistry
TopicAnalytical chemistry methods development
Canadian institutionsUniversity of Waterloo
Fundersnot available
KeywordsAnalyteSample preparationCoatingSampling (signal processing)Process engineeringSample (material)Solid-phase microextractionChemistryBioanalysisMatrix (chemical analysis)ChromatographyNanotechnologyComputer scienceMaterials scienceEngineeringMass spectrometryGas chromatography–mass spectrometry

Abstract

fetched live from OpenAlex

In recent years there has been considerable interest in developing techniques to monitor levels of biologically active compounds in living systems in natural environments. These efforts represent a significant departure from conventional ‘sampling’ techniques, where a portion of the system under study is removed from its natural environment, and the compounds of interest extracted and analyzed in a laboratory environment. An in vivo sampling approach can eliminate errors and reduce the time associated with sample transport and storage, and can therefore result in the collection of more accurate, precise, and faster analytical data. An ideal in vivo sampling technique should be portable, solvent-free, and offer integration of the sampling, sample preparation and sample analysis steps. These requirements are met by two techniques based on coated fibre and membrane technologies, presently under development in our laboratory.[1] Fibre solid-phase microextraction (fibreSPME) involves exposing a polymer-coated fused silica fibre to a sample. The analytes partition into the fibre coating until an equilibrium is reached. The fibre is then removed from the solution and the analytes are desorbed in the injector or injection loop of an analytical instrument such as a gas chromatograph (GC). The fibre is contained in a syringe-like device to facilitate handling.[2] Fibre-SPME can be used for both spot and time-averaged sampling. For spot sampling, the fibre is typically exposed to a sample matrix until the partitioning equilibrium between sample matrix and the coating material is reached. In the time-averaged technique the fibre remains in the needle during exposure of the SPME device to the sample. The fibre coating works as a trap for analytes that diffuse into the needle. In membrane extraction with a sorbent interface (MESI) a polymeric hollow fibre or a flat sheet membrane, in contact with a sample, is fitted directly into the carrier gas line of a GC equipped with a sorbent trap.[3]Analytes partition into the polymeric phase of the membrane and, after diffusion through the membrane, are carried by the gas to the sorbent trap. The concentrated analytes are periodically delivered onto the front of the column by a thermal pulse. MESI is a dynamic system, where the rate of analyte intake is dependent on both the diffusion coefficients of analytes in the membrane material and the membrane/sample matrix distribution constant. Similar to fibre-SPME, MESI can be used for both spot and time averaged monitoring. Both fibre-SPME and MESI techniques integrate sampling, sample preparation, and sample introduction to the analytical instrument, into a simple procedure. In fibreSPME mechanical movement of the fibre is necessary, as the sampling and sample introduction steps are separated in space, allowing one instrument to analyse large numbers of fibres. MESI, on the other hand, requires a dedicated, permanently attached instrument to one or several membrane/sorbent systems, eliminating the need for mechanical movement and therefore reducing the possibility of failure. MESI is thus suitable for continuous operation, allowing conversion of the analytical separation and detection instrument into a sensor-like device suitable for monitoring operations. Calibration procedures can be made very simple in both methods. For example, in air monitoring, the air/coating distribution constant can be estimated using the linear temperature-programmed retention index system (LTPRI). This allows quantification, even without identification, as long as the stationary phase used in the analytical column is identical to the fibre coating. The diffusion coefficient can be calculated by knowing the molecular weight of the target compound. To facilitate analysis of very polar analytes, a derivatization procedure can be used. For example, the validation field measurement of formaldehyde in ambient air, using both spot and time average sampling, was conducted using several techniques. Similar results were obtained for this challenging analyte using fibre-SPME and other more established procedures.[4]

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.003
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.324
Threshold uncertainty score0.431

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.003
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.056
GPT teacher head0.316
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2003
Admission routes1
Has abstractyes

Explore more

Same venueAustralian Journal of ChemistrySame topicAnalytical chemistry methods developmentFrench-language works237,207