MétaCan
Menu
Back to cohort
Record W2146023381 · doi:10.1148/radiol.2532081941

Quantification of Trapped Gas with CT and<sup>3</sup>He MR Imaging in a Porcine Model of Isolated Airway Obstruction

2009· article· en· W2146023381 on OpenAlexaff
Caterina Salito, Andréa Aliverti, David S. Gierada, Gaëtan Deslée, Richard A. Pierce, Peter T. Macklem, Jason C. Woods

Bibliographic record

VenueRadiology · 2009
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAtomic and Subatomic Physics Research
Canadian institutionsMcGill UniversityChristie (Canada)
FundersNational Heart, Lung, and Blood InstituteU.S. Public Health ServiceNational Institutes of HealthRegione Lombardia
KeywordsMedicineNuclear medicineMagnetic resonance imagingLung volumesVolume (thermodynamics)LungComputed tomographicHeliumNuclear magnetic resonanceComputed tomographyRadiologyPhysicsAtomic physicsInternal medicine

Abstract

fetched live from OpenAlex

PURPOSE: To quantify regional gas trapping in the lung by using computed tomographic (CT)-determined specific gas volume and hyperpolarized helium 3 ((3)He) magnetic resonance (MR) imaging in a porcine model of airway obstruction. MATERIALS AND METHODS: Four porcine lungs were removed after sacrifice for unrelated cardiac experiments, for which animal studies approval was obtained. Dynamic expiratory thin-section CT and (3)He MR imaging were performed during passive deflation from total lung capacity after obstructions were created with inverted one-way endobronchial exit valves in segmental or lobar bronchi to produce identifiable regions of trapped gas. Changes in specific gas volume were assessed from CT data for defined regions of interest within and outside of obstructed segments and for entire lobes. Helium 3 data were analyzed according to the corresponding regional signal reduction during expiration, compared with the total magnetic moment at each time point. RESULTS: In 4.5 seconds of free collapse, volume decreased by 6% +/- 2 (standard error) and 53% +/- 3, respectively, in trapped-gas lobes and in unobstructed regions (P < .0001). Specific gas volume changed by 6% +/- 2 in areas of trapped gas and decreased by 56% +/- 3 in unobstructed regions, from 3.4 mL/g +/- 0.2 to 1.5 mL/g +/- 0.1 (P < .0001). The (3)He signal intensity decreased by 25% +/- 6 and 71% +/- 3, respectively, in trapped-gas and normal regions (P = .0008). In unobstructed regions, the percentage decreases in specific gas volume and (3)He signal intensity were not statistically different from one another (P = .89). CONCLUSION: The results obtained from the model of gas trapping demonstrate that CT-determined specific gas volume and (3)He MR imaging can help identify and quantify the extent of regional trapped gas in explanted porcine lungs.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.003

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.000
Science and technology studies0.0000.001
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.260
Teacher spread0.245 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations20
Published2009
Admission routes1
Has abstractyes

Explore more