MétaCan
Menu
Back to cohort
Record W2146844333 · doi:10.1259/dmfr/22185511

Attitude of the Belgian dentist population towards radiation protection

2004· article· en· W2146844333 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueDentomaxillofacial Radiology · 2004
Typearticle
Languageen
FieldDentistry
TopicDental Radiography and Imaging
Canadian institutionsnot available
Fundersnot available
KeywordsDental radiographyRadiation protectionRadiographyMedicineRadiation doseRadiation exposureQuarter (Canadian coin)PopulationDentistryEffective dose (radiation)Lead apronMedical physicsNuclear medicineEnvironmental healthRadiology

Abstract

fetched live from OpenAlex

OBJECTIVES: To perform a survey of private dental offices in Belgium and gain insight in the knowledge and attitude of Belgian dentists towards quality care in radiography and radiation protection. METHODS: A questionnaire was distributed among 700 Belgian dental offices, which were included based on demographic data and the use of intraoral radiographic equipment. RESULTS: The response rate was 71%. Implementation of standards for quality care and radiation protection was suboptimal. In most offices, exposure settings of the intraoral radiation tube were 65 kV/kVp to 70 kV/kVp and 10 mA to 12 mA, with an average exposure time of 0.45 s. No reduction of exposure time was noticed when using faster film types. About one-third of the responders worked with digital image receptors. Aiming devices and rectangular collimation were used in a minority of practices (40% and 6%, respectively). The distance of the dentist to the radiation tube during exposure was on average 2.2 m, although 8% of the dentists assisted in holding the image receptor inside the patient's mouth. One quarter of the dentists were standing behind a wall when taking radiographs. Lead aprons were worn more often by female dentists. Dose estimation revealed that male dentists received a significantly larger effective dose per year than female dentists (8.3 mSv vs 3.2 mSv). CONCLUSIONS: The implementation of standards of quality care for radiography and radiation protection could be improved among Belgian dentists. An elaborate educational programme in dental radiography is a prerequisite. Furthermore, recommendations could help to attain a change in attitude towards the use of ionizing radiation in order to meet European guidelines.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.154
Threshold uncertainty score0.616

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.001
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.013
GPT teacher head0.267
Teacher spread0.254 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it