MétaCan
Menu
Back to cohort

Placebo-Controlled, Randomized Clinical Trial of Azimilide for Prevention of Ventricular Tachyarrhythmias in Patients With an Implantable Cardioverter Defibrillator

2004· article· en· W2147134314 on OpenAlex
Paul Dorian, Martin Borggrefe, Hussein R. Al‐Khalidi, Stefan H. Hohnloser, José M. Brum, Daljit Tatla, Johannes Brachmann, Robert J. Myerburg, David S. Cannom, Michael van der Laan, Michael J. Holroyde, Igor Singer, Craig M. Pratt

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueCirculation · 2004
Typearticle
Languageen
FieldMedicine
TopicCardiac pacing and defibrillation studies
Canadian institutionsSt. Michael's Hospital
Fundersnot available
KeywordsMedicineVentricular fibrillationVentricular tachycardiaCardiologyPlaceboInternal medicineAnesthesiaHazard ratioImplantable cardioverter-defibrillatorConcomitantAntiarrhythmic agentHeart diseaseConfidence interval

Abstract

fetched live from OpenAlex

BACKGROUND: Although implanted cardioverter defibrillators (ICDs) effectively treat sustained ventricular tachyarrhythmias, up to 50% of ICD recipients eventually require concomitant antiarrhythmic drug therapy to prevent symptomatic arrhythmia recurrences and hence reduce the number of device therapies. METHODS AND RESULTS: A total of 633 ICD recipients were enrolled in a randomized, double-blind, placebo-controlled study to evaluate the effect of daily doses of 75 or 125 mg of azimilide on recurrent symptomatic ventricular tachyarrhythmias and ICD therapies. Total all-cause shocks plus symptomatic ventricular tachycardia (VT) terminated by antitachycardia pacing (ATP) were significantly reduced by azimilide, with relative risk reductions of 57% (hazard ratio [HR]=0.43, 95% CI 0.26 to 0.69, P=0.0006) and 47% (HR=0.53, 95% CI 0.34 to 0.83, P=0.0053) at 75- and 125-mg doses, respectively. The reductions in all-cause shocks with both doses of azimilide did not achieve statistical significance. The incidence of all appropriate ICD therapies (shocks or ATP-terminated VT) was reduced significantly among patients taking 75 mg of azimilide (HR=0.52, 95% CI 0.30 to 0.89, P=0.017) and those taking 125 mg of azimilide (HR=0.38, 95% CI 0.22 to 0.65, P=0.0004). Five patients in the azimilide groups and 1 patient in the placebo group had torsade de pointes; all were successfully treated by the device. One patient taking 75 mg of azimilide had severe but reversible neutropenia. CONCLUSIONS: Azimilide significantly reduced the recurrence of VT or ventricular fibrillation terminated by shocks or ATP in ICD patients, thereby reducing the burden of symptomatic ventricular tachyarrhythmia.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Randomized trial · Consensus signal: Randomized trial
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.015
Threshold uncertainty score0.368

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.001
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.025
GPT teacher head0.319
Teacher spread0.295 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it