MétaCan
Menu
Back to cohort
Record W2147712979 · doi:10.2215/cjn.06680810

A Validation Study of the Canadian Organ Replacement Register

2011· article· en· W2147712979 on OpenAlexaffabout
Louise Moist, Heather Richards, Dana C. Miskulin, Charmaine E. Lok, Karen Yeates, Amit X. Garg, Lilyanna Trpeski, Ann Chapman, Joseph Emmanuel Amuah, Brenda R. Hemmelgarn

Bibliographic record

VenueClinical Journal of the American Society of Nephrology · 2011
Typearticle
Languageen
FieldMedicine
TopicChronic Kidney Disease and Diabetes
Canadian institutionsUniversity of CalgaryToronto General HospitalLondon Health Sciences CentreQueen's UniversityCanadian Institute for Health InformationWestern University
Fundersnot available
KeywordsMedicineMedical recordHazard ratioInternal medicineCohortConfidence intervalDiagnosis codeDialysisKidney diseaseEmergency medicinePopulation

Abstract

fetched live from OpenAlex

BACKGROUND AND OBJECTIVES: Accurate and complete documentation of patient characteristics and comorbidities in renal registers is essential to control bias in the comparison of outcomes across groups of patients or dialysis facilities. The objectives of this study were to assess the quality of data collected in the Canadian Organ Replacement Register (CORR) compared with the patient's medical charts. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS: This cohort study of a representative sample of adult, incident patients registered in CORR in 2005 to 2006 examined the prevalence, sensitivity, specificity, positive and negative predictive values, and κ of comorbid conditions and agreement in coding of patient demographics and primary renal disease between CORR and the patient's medical record. The effect of coding variation on patient survival was evaluated. RESULTS: Medical records on 1125 patients were reviewed. Agreement exceeded 97% for health card number, date of birth, and sex and 71% (range 46.6 to 89.1%) for the primary renal disease. Comorbid conditions were under-reported in CORR. Sensitivities ranged from 0.89 (95% confidence interval 0.80, 0.92) for hypertension to 0.47 (0.38, 0.55) for peripheral vascular disease. Specificity was >0.93 for all comorbidities except hypertension. Hazard ratios for death were similar whether calculated using data from CORR or the medical record. CONCLUSIONS: Comorbid conditions are under-reported in CORR; however, the associated risks of mortality were similar whether using the CORR data or the medical record data, suggesting that CORR data can be used in clinical research with minimal concern for bias.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.019
metaresearch head score (Gemma)0.071
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.982
Threshold uncertainty score0.131

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0190.071
Meta-epidemiology (narrow)0.0010.001
Meta-epidemiology (broad)0.0010.001
Bibliometrics0.0030.007
Science and technology studies0.0030.001
Scholarly communication0.0020.001
Open science0.0030.002
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0020.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.082
GPT teacher head0.357
Teacher spread0.275 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations71
Published2011
Admission routes2
Has abstractyes

Explore more

Same venueClinical Journal of the American Society of NephrologySame topicChronic Kidney Disease and DiabetesFrench-language works237,207