MétaCan
Menu
Back to cohort
Record W2147886131 · doi:10.1080/15389588.2014.880886

Development, Calibration, and Validation of a Head–Neck Complex of THOR Mod Kit Finite Element Model

2014· article· en· W2147886131 on OpenAlexfundno aff
Jacob B. Putnam, Jeffrey T. Somers, Costin D. Untaroiu

Bibliographic record

VenueTraffic Injury Prevention · 2014
Typearticle
Languageen
FieldMedicine
TopicAutomotive and Human Injury Biomechanics
Canadian institutionsnot available
FundersUniversité de SherbrookeNational Aeronautics and Space Administration
KeywordsHybrid IIICrash testParametric statisticsKinematicsCalibrationHead (geology)Finite element methodCrashSimulationParametric modelHead and neckComputer scienceStructural engineeringEngineeringMathematicsSurgeryStatisticsMedicine

Abstract

fetched live from OpenAlex

INTRODUCTION/OBJECTIVE: In an effort to continually improve upon the design of the test device for human occupant restraint (THOR) dummy, a series of modifications have recently been applied. The first objective of this study was to update the THOR head-neck finite element (FE) model to the specifications of the latest dummy modifications. The second objective was to develop and apply a new optimization-based methodology to calibrate the FE head-neck model based on experimental test data. The calibrated head-neck model was validated against both frontal and lateral impact test data. Finally, the sensitivities of the model, in terms of head and neck injury criteria, to pretest positioning conditions were evaluated in a frontal crash test simulation. METHODS: The updated parts of the head-neck THOR FE model were remeshed from CAD geometries of the modified parts. In addition, further model modifications were made to improve the effectiveness of the model (e.g., model stability). A novel calibration methodology, which incorporates the CORA (CORelation and Analysis) rating system with an optimization algorithm implemented in Isight software, was developed to improve both kinematic and kinetic responses of the model in various THOR dummy certification and biomechanical response tests. A parametric study was performed to evaluate head and neck injury criteria values in the calibrated head-neck model during a 40 km/h frontal crash test with respect to variation in the THOR model upper body and belt pretest position. RESULTS: Material parameter optimization was shown to greatly improve the updated model response by increasing the average rating score from 0.794 ± 0.073 to 0.964 ± 0.019. The calibrated neck showed the biggest improvement in the pendulum flexion simulation from 0.681 in the original model up to 0.96 in the calibrated model. The fully calibrated model proved to be effective at predicting dummy response in frontal and lateral loading conditions during the validation phase (0.942 average score). Upper body position was shown to have a greater effect on head-neck response than belt position. The pretest positioning variation resulted in a 10 percent maximum change in HIC36 values and 14 percent maximum change in NIJ values. CONCLUSION: The optimization-based calibration methodology was effective as it markedly improved model performance. The calibrated head-neck model demonstrated application in a crash safety analysis, showing slight head-neck injury sensitivity to pretest positioning in a frontal crash impact scenario.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Simulation or modeling · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.805
Threshold uncertainty score0.489

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.318
Teacher spread0.268 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designSimulation or modeling
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations21
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueTraffic Injury PreventionSame topicAutomotive and Human Injury BiomechanicsFrench-language works237,207