MétaCan
Menu
Back to cohort
Record W2148069775 · doi:10.1002/jbm.a.31146

Design of a biomimetic polymer‐composite hip prosthesis

2007· article· en· W2148069775 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.
fundA Canadian funder is recorded on the work.

Bibliographic record

VenueJournal of Biomedical Materials Research Part A · 2007
Typearticle
Languageen
FieldMedicine
TopicOrthopaedic implants and arthroplasty
Canadian institutionsNational Research Council CanadaPolytechnique Montréal
FundersNatural Sciences and Engineering Research Council of Canada
KeywordsMaterials scienceComposite numberPolymerComposite materialProsthesisBiomedical engineeringComputer scienceEngineeringArtificial intelligence

Abstract

fetched live from OpenAlex

A new biomimetic composite hip prosthesis (stem) was designed to obtain properties similar to those of the contiguous bone, in particular stiffness, to allow normal loading of the surrounding femoral bone. This normal loading would reduce excessive stress shielding, known to result in bone loss, and micromotions at the bone-implant interface, leading to aseptic prosthetic loosening. The design proposed is based on a hollow substructure made of hydroxyapatite-coated, continuous carbon fiber (CF) reinforced polyamide 12 (PA12) composite with an internal soft polymer-based core. Different composite configurations were studied to match the properties of host tissue. Nonlinear three-dimensional analysis of the hip prosthesis was carried out using a three-dimensional finite element bone model based on the composite femur. The performance of composite-based hip and titanium alloy-based (Ti-6Al-4V) stems embedded into femoral bone was compared. The effect of core stiffness and ply configuration was also analyzed. Results show that stresses in composite stem are lower than those in Ti stem, and that the femoral bone implanted with composite structure sustains more load than the one implanted with Ti stem. Micromotions in the composite stem are significantly smaller than those in Ti stem over the entire bone-implant surface because of the favorable interfacial stress distribution.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.010
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesInsufficient payload (model declined to judge)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: Bench or experimental
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.023
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0100.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.079
GPT teacher head0.379
Teacher spread0.300 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it