MétaCan
Menu
Back to cohort
Record W2148659521 · doi:10.1109/pac.1995.505386

A comparison of two injection line matching sections for compact cyclotrons

2002· article· en· W2148659521 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

affAt least one author lists a Canadian institution in the pinned OpenAlex snapshot.

Bibliographic record

VenueProceedings Particle Accelerator Conference · 2002
Typearticle
Languageen
FieldEngineering
TopicParticle accelerators and beam dynamics
Canadian institutionsTRIUMF
Fundersnot available
KeywordsCyclotronThermal emittancePhysicsQuadrupoleSolenoidTransmission lineBeam emittanceLine (geometry)OpticsNuclear physicsBeam (structure)Atomic physicsComputer scienceTelecommunicationsPlasmaMathematicsGeometry

Abstract

fetched live from OpenAlex

Two versions of injection line matching sections between the external ion source and the spiral inflector are used for the compact cyclotrons developed at TRIUMF in cooperation with Ebco Technologies. The 30 MeV model adopts a solenoid-doublet (SQQ) version while the 19 MeV unit takes a four quadrupole/two quadrupole (4Q/2Q) option. Both cyclotrons use a same type of H cusp source and an identical inflector-central region combination. A comparison has been made between these two systems, in terms of DC transmission and RF acceptance as a function of source's H current intensity and emittance. The design and optics characteristics for both systems are described and the results obtained are reported.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.688
Threshold uncertainty score0.947

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.001
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.078
GPT teacher head0.321
Teacher spread0.243 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it