MétaCan
Menu
Back to cohort
Record W2149396230 · doi:10.1109/nssmic.2003.1352313

Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET

2003· article· en· W2149396230 on OpenAlexaff
Lefteris Livieratos, Lars Stegger, P Bloomfield, Klaus Schäfers, Dale L. Bailey, Paolo G. Camici

Bibliographic record

Venue2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515) · 2003
Typearticle
Languageen
FieldMedicine
TopicMedical Imaging Techniques and Applications
Canadian institutionsCentre for Addiction and Mental Health
Fundersnot available
KeywordsImaging phantomComputer visionProjection (relational algebra)Computer scienceArtificial intelligenceMedical imagingFiducial markerIterative reconstructionScannerCorrection for attenuationImage registrationCentroidNuclear medicineAlgorithmPositron emission tomographyMedicineImage (mathematics)

Abstract

fetched live from OpenAlex

Respiratory motion is a source of artefacts and quantification errors in cardiac imaging. Preliminary studies with retrospective respiratory gating in PET support the observation of other imaging modalities of a rigid-body motion of the heart during respiration. However, the use of gating techniques to eliminate motion may result in poor count statistics per reconstructed image. We have implemented a motion correction technique which applies rigid-body transformations on list-mode data event-by-event on the basis of a geometric model of intersection of the lines-of-response with the scanner. Pre-correction for detector efficiencies and photon attenuation before transformation are included in the process. Projection data are acquired together with physiological signal (every ms) from an inductive respiration monitor with an elasticised belt at chest level. Data are retrospectively sorted into separate respiratory gates on an off-line workstation. Transformation parameters relating the gated images, estimated by means of image registration, can be applied on the original list-mode data to obtain a single motion-corrected dataset. The accuracy of the technique was assessed with point source data and a good correlation between applied and measured transformations, estimated from the centroid of the source, was observed. The technique was applied on phantom data with simulated respiratory motion and on patient data with C/sup 15/O and /sup 18/FDG. Quantitative assessment of preliminary C/sup 15/O patient datasets showed at least 4.5% improvement in the recovery coefficient at the centre of the left ventricle.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.006
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: none
Teacher disagreement score0.005
Threshold uncertainty score0.016

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.006
Meta-epidemiology (narrow)0.0010.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.001
Open science0.0010.001
Research integrity0.0010.001
Insufficient payload (model declined to judge)0.0050.004

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.049
GPT teacher head0.341
Teacher spread0.292 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations1
Published2003
Admission routes1
Has abstractyes

Explore more

Same venue2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515)Same topicMedical Imaging Techniques and ApplicationsFrench-language works237,207