MétaCan
Menu
Back to cohort
Record W2150327468 · doi:10.1080/15459620490497744

Evaluation and Determinants of Airborne Bacterial Concentrations in School Classrooms

2004· article· en· W2150327468 on OpenAlexaffabout
Karen H. Bartlett, Susan Kennedy, Michael Bräuer, Chris van Netten, Barbara Dill

Bibliographic record

VenueJournal of Occupational and Environmental Hygiene · 2004
Typearticle
Languageen
FieldEnvironmental Science
TopicIndoor Air Quality and Microbial Exposure
Canadian institutionsUniversity of British Columbia
FundersBDU.S. Environmental Protection Agency
KeywordsEnvironmental scienceIndoor bioaerosolRelative humidityOccupancyBioaerosolIndoor air qualityVentilation (architecture)Indoor airAerosolToxicologyAtmospheric sciencesEnvironmental healthEnvironmental engineeringMeteorologyGeographyEcologyMedicineBiology

Abstract

fetched live from OpenAlex

A survey of 39 elementary schools was undertaken to determine indoor air concentrations of bioaerosols within a coastal, temperate climatic zone in British Columbia, Canada. This article reports the results for airborne bacteria. Determinants of exposure were grouped into environmental (outdoor temperature, relative humidity, season, weather), ventilation and comfort parameter (indoor relative humidity, temperature, indoor CO2 concentration, indoor fungal concentration), and occupancy (number of occupants, activity levels, occupancy patterns) variables. Regression modeling was used to evaluate the association between these factors and measured concentrations of indoor mesophilic bacteria. Naturally ventilated rooms (47% of the total rooms surveyed) had higher bacterial counts than mechanically ventilated rooms (geometric mean 325 vs. 166 CFU/m3, respectively, p < 0.001). In univariate analyses, bacterial counts were negatively correlated with supply and exhaust flow rates, air exchange rates, and the percentage of the day that occupants spent quietly sitting at their desks. Analysis of bacterial groups indicated various sources of the bacterial aerosol, with micrococci and staphylococci closely associated with occupancy variables, Bacillus with site and occupancy, and coryneform bacteria with site variables only. Approximately 60% of the variance in the outcome measurement of total bacteria was accountedfor by indoor CO2, lower air exchange rate, the age of the building, signs of current or old moisture stains, room volume, indoor relative humidity, and occupant activity level in a multiple linear regression model, with ventilation factors accounting for 40% of the variance.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.002
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.090
Threshold uncertainty score0.179

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0000.002
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0010.001
Science and technology studies0.0000.000
Scholarly communication0.0010.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.019
GPT teacher head0.273
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations77
Published2004
Admission routes2
Has abstractyes

Explore more

Same venueJournal of Occupational and Environmental HygieneSame topicIndoor Air Quality and Microbial ExposureFrench-language works237,207