MétaCan
Menu
Back to cohort
Record W2151698577 · doi:10.1177/112067210801800311

Comparison of Clinical Results between Heparin Surface Modified Hydrophilic Acrylic and Hydrophobic Acrylic Intraocular Lens

2008· article· en· W2151698577 on OpenAlex

Why this work is in the frame

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

aboutThe title or abstract carries a Canadian signal from the geographic lexicon.
no affNo Canadian affiliation: this work is invisible to an affiliation-only frame.
No Canadian affiliation. An affiliation-only frame, the usual design, would never have seen this work. It is one of the works that make the case for inverting the frame.

Bibliographic record

VenueEuropean Journal of Ophthalmology · 2008
Typearticle
Languageen
FieldMedicine
TopicIntraocular Surgery and Lenses
Canadian institutionsnot available
Fundersnot available
KeywordsIntraocular lensOphthalmologyAcrylic polymerAcrylic resinLens (geology)Intraocular lensesAcrylic acidPolymer chemistryMaterials scienceMedicineCopolymerPolymerOpticsComposite material

Abstract

fetched live from OpenAlex

PURPOSE: To compare the clinical results of heparin surface modified (HSM) hydrophilic acrylic intraocular lens (IOL) with those of hydrophobic acrylic IOL. METHODS: One hundred patients with cataract were randomized to receive one of acrylic foldable IOLs after phacoemulsification: HSM hydrophilic acrylic IOL (n=50) BioVue3 (BioVue, OII, Ontario, CA, USA) and hydrophobic acrylic IOL (n=50) Sensar (AR40e, AMO, Santa Ana, CA, USA). Bestcorrected visual acuity and refractive error were measured at 1 week, 2 months, 6 months and 12 months after surgery in both IOL groups. To assess posterior capsular opacification (PCO), digital retroillumination image of posterior capsule was analyzed at 12 months using POCOman software. RESULTS: Best-corrected visual acuity (log MAR) was 0.032+/-0.082 in BioVue3 group and 0.034+/-0.077 in Sensar group at 12 months. There was no statistically significant difference between the two groups (p=0.554). Refractive error was -0.247+/-0.821 diopter in BioVue3 group and -0.264+/-0.808 diopter in Sensar group at 12 months. There was no statistically significant difference of refractive error between the two groups (p=0.909). At 12 months, BioVue3 IOL group had a lower percentage area and severity of PCO than Sensar group. However, it was not statistically significant (p=0.349, p=0.288). No Nd:YAG capsulotomy was performed in BioVue3 group while it was required in two eyes (4.0%) in Sensar group. CONCLUSIONS: There was no statistically significant difference of postoperative visual acuity, refractive error and degree of PCO between HSM hydrophilic acrylic IOL and hydrophobic acrylic IOL.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.003
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesMeta-epidemiology (narrow)
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.022
Threshold uncertainty score1.000

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0030.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0020.000
Bibliometrics0.0000.000
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.166
GPT teacher head0.391
Teacher spread0.224 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it