MétaCan
Menu
Back to cohort
Record W2151753024 · doi:10.1136/bjo.2004.060780

Minimally invasive, direct, real time measurement of drug concentration in the anterior eye

2005· article· en· W2151753024 on OpenAlexfundno aff
Joe Miller

Bibliographic record

VenueBritish Journal of Ophthalmology · 2005
Typearticle
Languageen
FieldMedicine
TopicOcular Surface and Contact Lens
Canadian institutionsnot available
FundersEngineering and Physical Sciences Research CouncilHospital for Sick Children
KeywordsCuvetteAbsorbanceFluoresceinBrimonidineDrug detectionContact lensCorneaAbsorption (acoustics)Biomedical engineeringHuman eyeLens (geology)OpticsOphthalmologyMedicineChromatographyFluorescenceGlaucomaChemistry

Abstract

fetched live from OpenAlex

AIMS: To evaluate a corneal contact lens which effectively turns the anterior chamber of the eye into a cuvette, enabling the concentration of a drug to be measured using absorption spectroscopy. METHODS: A hand held contact lens incorporating optical fibres connected to a spectrograph enabled a beam of light to be directed in, across, and out of the anterior chamber. The device was used to follow the time course of drug concentration in the anterior chamber of rabbit (sedated) and humans, using topical brimonidine or fluorescein (with or without local anaesthesia). Absorbance measurements were taken for a 5-25 second period, repeated every 30 minutes. Drug concentrations were compared using absorbance peak height. RESULTS: Corneal absorption starts to rise rapidly at wavelengths shorter than 315 nm. The light path within the anterior chamber is 6.9 mm (rabbit) and 5.8 mm (human), the absorbance measured also includes a corneal component. Application of fluorescein (three drops of 2% solution) in rabbit allowed detection, 60 minutes later, of a large absorbance peak at 490 nm. In the human eye, the device could not measure fluorescein (applied as in rabbit), but clearly detected brimonidine for 3 hours following topical application of 0.6 mg. Modification of the device to measure fluorescence resulted in the detection of 5.3 nM fluorescein in the ex vivo rabbit eye, an increase in sensitivity of two orders of magnitude over the absorption measurements. CONCLUSION: This device has the potential to allow repeated measurements of drug concentrations in the anterior eye provided the drug has suitable absorption or fluorescence characteristics.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.491
Threshold uncertainty score0.285

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.016
GPT teacher head0.268
Teacher spread0.251 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations3
Published2005
Admission routes1
Has abstractyes

Explore more

Same venueBritish Journal of OphthalmologySame topicOcular Surface and Contact LensFrench-language works237,207