MétaCan
Menu
Back to cohort
Record W2151799642 · doi:10.7863/jum.2006.25.7.845

Contribution of Tissue Harmonic Imaging and Frequency Compound Imaging in Interventional Breast Sonography

2006· article· en· W2151799642 on OpenAlexaff
Benoı̂t Mesurolle, Harjinder J. S. Bining, Mona El Khoury, Amina Barhdadi, Ellen Kao

Bibliographic record

VenueJournal of Ultrasound in Medicine · 2006
Typearticle
Languageen
FieldMedicine
TopicUltrasound Imaging and Elastography
Canadian institutionsRoyal Victoria HospitalMcGill University Health Centre
Fundersnot available
KeywordsMedicineRadiologyLesionTarget lesionUltrasoundBreast imagingImage qualitySecond-harmonic imaging microscopyNuclear medicineMammographySurgeryBreast cancerInternal medicineCancer

Abstract

fetched live from OpenAlex

OBJECTIVE: The purpose of this study was to retrospectively compare conventional imaging, frequency compound imaging (CI), and tissue harmonic imaging (THI) in interventional breast sonography. METHODS: Institutional Review Board approval and patient informed consent were not required. The authors reviewed 104 sonographically guided breast procedures in 83 patients. For each biopsy, 4 images obtained with conventional imaging, frequency CI at 10 and 14 MHz (CI10 and CI14), and THI were graded independently by 2 radiologists for lesion conspicuity, needle conspicuity, lesion and needle conspicuity, and overall image quality. Frequency CI at 10 MHz, CI14, and THI were compared with conventional imaging. Different clinical scenarios (fatty versus glandular background, fine needle versus core needle, and oblique versus horizontal needle direction) were evaluated. RESULTS: Statistical analysis showed that for overall image quality, CI10 was the best setting (odds ratios [OR], 3.67 and 7.48). For lesion conspicuity, CI14 (OR, 3.55) and THI (OR, 1.77) improved lesion visibility in a fatty background, whereas THI (OR, 0.26) was very limited in a glandular background. For needle conspicuity, no setting was better than conventional, whereas THI was the least valuable setting (OR, 0.011 and 0.049). For lesion and needle conspicuity, CI10 showed significantly better results than conventional for a dense background (P = .0268 and .4028; OR, 2.435 and 1.383) with 1 reviewer, whereas THI was the least valuable setting (OR, 0.014 and 0.042). CONCLUSIONS: Conventional imaging provided the best assessment of lesion and needle conspicuity. Frequency compounding is a useful setting for dense breast and for fine-needle aspiration. Tissue harmonic imaging has a role in the visualization of a lesion against a fatty background but is of limited value in needle visualization.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.173
Threshold uncertainty score0.690

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0010.001
Science and technology studies0.0000.001
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.267
Teacher spread0.260 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations34
Published2006
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Ultrasound in MedicineSame topicUltrasound Imaging and ElastographyFrench-language works237,207