MétaCan
Menu
Back to cohort
Record W2151973047 · doi:10.1120/jacmp.v14i2.3692

An investigation into the use of MMCTP to tune accelerator source parameters and testing its clinical application

2013· article· en· W2151973047 on OpenAlexaff
Elaine Conneely, Andrew Alexander, Gabriella Stroian, Jan Seuntjens, Mark Foley

Bibliographic record

VenueJournal of Applied Clinical Medical Physics · 2013
Typearticle
Languageen
FieldPhysics and Astronomy
TopicAdvanced Radiotherapy Techniques
Canadian institutionsMcGill UniversityMontreal General Hospital
Fundersnot available
KeywordsComputer scienceMedical physicsNuclear engineeringNuclear physicsPhysicsEngineering

Abstract

fetched live from OpenAlex

This paper presents an alternative method to tune Monte Carlo electron beam parameters to match measured data using a minimal set of variables in order to reduce the model setup time prior to clinical implementation of the model. Monte Carlo calculations provide the possibility of a powerful treatment planning verification technique. The nonstandardized and nonautomated process of tuning the required accelerator model is one of the reasons for delays in the clinical implementation of Monte Carlo techniques. This work aims to establish and verify an alternative tuning method that can be carried out in a minimal amount of time, allowing it to be easily implemented in a clinical setting by personnel with minimal experience with Monte Carlo methods. This tuned model can then be incorporated into the MMCTP system to allow the system to be used as a second dose calculation check for IMRT plans. The technique proposed was used to establish the primary electron beam parameters for accelerator models for the Varian Clinac 2100 6 MV photon beam using the BEAMnrc Monte Carlo system. The method is intended to provide a clear, direct, and efficient process for tuning an accelerator model using readily available clinical quality assurance data. The tuning provides a refined model, which agrees with measured dose profile curves within 1.5% outside the penumbra or 3 mm in the penumbra, for square fields with sides of 3 cm up to 30 cm. These models can then be employed as the basis for Monte Carlo recalculations of dose distributions, using the MMCTP system, for clinical treatment plans, providing an invaluable assessment tool. This was tested on six IMRT plans and compared to the measurements performed for the pretreatment QA process. These Monte Carlo values for the average dose to the chamber volume agreed with measurements to within 0.6%.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Other design · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.944
Threshold uncertainty score0.478

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.001
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.090
GPT teacher head0.384
Teacher spread0.294 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designOther design
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations18
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Applied Clinical Medical PhysicsSame topicAdvanced Radiotherapy TechniquesFrench-language works237,207