Programmable current source dedicated to implantable microstimulators
Bibliographic record
Abstract
In this paper, a survey of programmable current-source architectures based on miniaturized digital-to-analog converters (DAC) is elaborated to propose a new design dedicated to a visual microstimulator. The needed current-source constitutes the electronic interface to tissues. A few samples of this current-source will be integrated in an implantable device which is powered and controlled using an electromagnetic coupling technique. The main objective is to select a design that meets as close as possible criteria related to the implant such as reliability, flexibility, energy efficiency and integration area. Consequently, an adequate current source is proposed which is a 5-bit thermometer-code-based DAC architecture. The resulting circuit is simulated using a 0.35 /spl mu/m CMOS technology from PMC-Sierra available through the Canadian Microelectronics Corporation (CMC).
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
How this classification was reachedexpand
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.000 | 0.000 |
| Meta-epidemiology (narrow) | 0.000 | 0.000 |
| Meta-epidemiology (broad) | 0.000 | 0.000 |
| Bibliometrics | 0.000 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.000 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.000 |
| Insufficient payload (model declined to judge) | 0.000 | 0.001 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from itClassification
machine, unvalidatedMachine predicted; a candidate call from one teacher head, not a consensus.
How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".