MétaCan
← all works

Quantification of Proteins and Metabolites by Mass Spectrometry without Isotopic Labeling or Spiked Standards

2003· article· en· 651 citations· W2152180036 on OpenAlex· 10.1021/ac026468x

Why is this work in the frame?

A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.

Canadian funderA Canadian agency funded it. The work may carry no Canadian affiliation at all.

No Canadian affiliation. An affiliation-only frame — the usual design — would never have seen this work. It is one of the works that make the case for inverting the frame.

Machine scores (provisional)

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Opus teacher head0.012
GPT teacher head0.277
Teacher spread
0.265 · how far apart the two teachers sit on this one work
Validation status
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Abstract

A new method is presented for quantifying proteomic and metabolomic profile data by liquid chromatography-mass spectrometry (LC-MS) with electrospray ionization. This biotechnology provides differential expression measurements and enables the discovery of biological markers (biomarkers). Work presented here uses human serum but is applicable to any fluid or tissue. The approach relies on linearity of signal versus molecular concentration and reproducibility of sample processing. There is no use of isotopic labeling or chemically similar standard materials. Linear standard curves are reported for a variety of compounds introduced into human serum. As a measure of analytical reproducibility for proteome and metabolome sampling, median coefficients of variation of 25.7 and 23.8%, respectively, were determined for approximately 3400 molecular ions (not counting their numerous isotopes) from 25 independently processed human serum samples, corresponding to a total of 85000 individual molecular ion measurements.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

The record

Venue
Analytical Chemistry
Topic
Metabolomics and Mass Spectrometry Studies
Field
Biochemistry, Genetics and Molecular Biology
Canadian institutions
Funders
Canadian Institute for Theoretical Astrophysics
Keywords
ChemistryReproducibilityChromatographyMass spectrometryMetabolomeMetabolomicsProteomeElectrospray ionizationSample preparationIsotopeAnalytical Chemistry (journal)ProteomicsLabel-free quantificationQuantitative proteomicsBiochemistry
Has abstract in OpenAlex
yes