MétaCan
Menu
Back to cohort

Infrared Thermographic Evaluation of Temperature Modifications Induced during Implant Site Preparation with Cylindrical versus Conical Drills

2009· article· en· W2152728493 on OpenAlexvenueno aff
Antônio Scarano, Adriano Piattelli, Bartolomeo Assenza, Francesco Carinci, Luigi Donato, Gian Luca Romani, Arcangelo Merla

Bibliographic record

VenueClinical Implant Dentistry and Related Research · 2009
Typearticle
Languageen
FieldMedicine
TopicInfrared Thermography in Medicine
Canadian institutionsnot available
Fundersnot available
KeywordsDrillDrillingConical surfaceImplantMaterials scienceCortical boneThermographyDental implantBiomedical engineeringDentistryOrthodonticsComposite materialMedicineInfraredAnatomySurgeryOpticsMetallurgy

Abstract

fetched live from OpenAlex

BACKGROUND: A few studies have investigated the influence of drilling on bone healing. Many factors have been reported to influence temperature rise during surgical preparation for implant placement: drill geometry, drilling depth, sharpness of the cutting tool, drilling speed, pressure applied to the drill, use of graduated versus one-step drilling, intermittent versus continuous drilling, and use or not of irrigation. PURPOSE: The objective of this study was to quantify the temperature changes in cortical bone and at the apical portion of the drills during implant site preparation with a cylindrical implant drill versus a conical implant drill. MATERIALS AND METHODS: Two implant drill systems were evaluated in vitro using bovine femoral cortical bone. The two implant drill systems evaluated in this study were system A (a cylindrical drill with triple twist drills) (Bone System, Milano, Italy) and system B (a conical drill with quadruple twist drills) (Bone System). Site preparation began, and the temperature of the cortical bone and at the apical portion of the drill was measured by the infrared thermography. RESULTS: The mean temperature produced in the cortical bone during implant preparation was 31.2 ± 0.5°C for the cylindrical drills and 29.1 ± 0.6°C for the conical drill. The mean temperature produced in the apical portion of the drill during implant site preparation was 32.1 ± 0.7°C for the cylindrical drill system and 29.6 ± 0.6°C for the conical drill. Statistically significant differences were found in the temperature measurements in the cortical bone in the two groups (p < .05). A statistically significant difference was observed for the temperature measurements in the apical portion of the drill in the two groups (p < .005). DISCUSSION: The model system used in this work was able to evaluate the temperature in the cortical bone and in the apical portion of the drills; the temperature modifications in the apical portion of the drill seemed to be correlated to the drill geometry. The results of the present study showed that drill geometry seems to be an important factor in heat generation during implant site preparation. CONCLUSION: The drill geometry could explain the increased temperature in the apical portion of the drill.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.001
Threshold uncertainty score0.004

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.129
GPT teacher head0.467
Teacher spread0.339 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations112
Published2009
Admission routes1
Has abstractyes

Explore more

Same venueClinical Implant Dentistry and Related ResearchSame topicInfrared Thermography in MedicineFrench-language works237,207