MétaCan
Menu
Back to cohort
Record W2152822641 · doi:10.1002/ccd.20984

Feasibility of the PCI through 6F diagnostic catheters

2007· article· en· W2152822641 on OpenAlexaffabout
Pierre‐Frédéric Keller, Gilbert Gosselin, Jean‐Claude Grégoire, Antoine Guédès, Vitali Verin

Bibliographic record

VenueCatheterization and Cardiovascular Interventions · 2007
Typearticle
Languageen
FieldMedicine
TopicCoronary Interventions and Diagnostics
Canadian institutionsMontreal Heart Institute
Fundersnot available
KeywordsMedicineConventional PCICatheterTIMICoronary artery diseaseStentLumen (anatomy)CardiologyRadiologyCircumflexArteryMyocardial infarctionInternal medicineSurgery

Abstract

fetched live from OpenAlex

BACKGROUND: The choice of guiding catheter for optimal back-up support is critical in order to achieve a successful PCI. Diagnostic 6 French (F) catheters have an internal lumen diameter as large as 5F guiding catheters. The aim of this study was to demonstrate for the first time the feasibility of performing PCI with Cordis 6F diagnostic catheters in selected coronary lesions. METHODS: 32 coronary stents were implanted using 6F diagnostic catheters in 27 eligible patients at the Montreal Heart Institute. The inclusion criteria were TIMI angiographic score < B2 in native coronary arteries or in coronary artery bypass grafts. Bifurcations and left main disease were not included. RESULTS: Eighty-five percent of the patients underwent PCI for acute coronary syndromes (ACS). PCI was performed in 5 lesions (19%) of the left coronary circulation; in 21 lesions (78%) of the right coronary artery and in one lesion (4%) of the 1st obtuse marginal branch of the circumflex artery, through a left mammary artery bypass. Only stents suitable for 5F guiding catheters were used. The largest stent was 4.0 mm in diameter and 32 mm in length. Direct stenting was performed in 75% of patients. The angiographic success for PCI of target lesions was 100%, without clinical or angiographic complications. CONCLUSIONS: In selected cases, diagnostic 6F catheters can be used for PCI with 5F compatible balloons and stents. PCI via a diagnostic catheter may provide even better back-up support and allows for significant resources and time savings, especially in patients with ACS.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.001
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.134
Threshold uncertainty score0.391

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0010.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.002
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.050
GPT teacher head0.320
Teacher spread0.269 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations7
Published2007
Admission routes2
Has abstractyes

Explore more

Same venueCatheterization and Cardiovascular InterventionsSame topicCoronary Interventions and DiagnosticsFrench-language works237,207