MétaCan
Menu
Back to cohort
Record W2152934654 · doi:10.1002/jmri.24363

Diagnostic accuracy of dynamic gadoxetic‐acid–enhanced MRI and PET/CT compared in patients with liver metastases from neuroendocrine neoplasms

2013· article· en· W2152934654 on OpenAlexaff
Marco Armbruster, Christoph J. Zech, Steven Sourbron, Felix Ceelen, Christoph J. Auernhammer, Carsten Rist, Alexander Haug, Amit Singnurkar, Maximilian F. Reiser, Wieland H. Sommer

Bibliographic record

VenueJournal of Magnetic Resonance Imaging · 2013
Typearticle
Languageen
FieldMedicine
TopicMRI in cancer diagnosis
Canadian institutionsMcMaster University
Fundersnot available
KeywordsGadoxetic acidMedicineNuclear medicineMagnetic resonance imagingPositron emission tomographyStandardized uptake valueRadiologyNeuroendocrine tumorsDynamic contrast-enhanced MRIPET-CTPathologyGadolinium DTPA

Abstract

fetched live from OpenAlex

PURPOSE: To evaluate the diagnostic accuracy of dynamic-contrast-enhanced (DCE) MRI in comparison to both (18)F-FDG- and (68)Ga-DOTATATE-PET/CT in patients with liver metastases of neuroendocrine neoplasms (NEN). MATERIALS AND METHODS: Thirty-two patients with hepatic metastases from NEN were examined both in DCE-MRI and positron emission tomography/computed tomography (PET/CT), using either (18)F-fluorodeoxyglucose ((18)F-FDG) or (68)Ga-DOTATATE as tracer. DCE-MRI was performed at 3 Tesla with Gd-EOB-DTPA acquiring 48 slices every 2.2 s for 5 min. Three regions of interest (ROIs) representing liver background and liver metastases were defined in fat-saturated T1w three-dimensional GRE MRI sequences in the hepatobiliary phase. Corresponding ROIs were then defined in the DCE-MRI- and in the PET/CT-dataset. Area under the curve (AUC) was calculated for the differentiation between metastases and liver background for DCE-MRI and PET-CT parameters. RESULTS: AUC was very high for SUVmean (mean standardized uptake value) derived from (68)Ga-DOTATATE- (AUC = 0.966), and (18)F-FDG-PET/CT (AUC = 0.989). For DCE-MRI parameters, arterial flow fraction and intracellular uptake fraction showed the highest AUCs (AUC = 0.826, AUC = 0.819, respectively). The combination of those two had an AUC of 0.949. The combination of DCE-MRI and PET-CT parameters resulted in the highest AUC. CONCLUSION: Both PET/CT parameters and DCE-MRI perfusion parameters show a high diagnostic accuracy in the distinction between liver metastases and liver tissue. Our data suggest that both modalities provide complementary information.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.126
Threshold uncertainty score0.873

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0010.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.006
GPT teacher head0.238
Teacher spread0.232 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations31
Published2013
Admission routes1
Has abstractyes

Explore more

Same venueJournal of Magnetic Resonance ImagingSame topicMRI in cancer diagnosisFrench-language works237,207