MétaCan
Menu
Back to cohort

Clinical, angiographic and radiographic outcome differences among mechanical thrombectomy devices: initial experience of a large-volume center

2014· article· en· W2153563725 on OpenAlexaboutno aff
Tareq Kass-Hout, Omar Kass‐Hout, Chung‐Huan Sun, Taha Kass‐Hout, Samir Belagaje, Aaron Anderson, Michael Frankel, Rishi Gupta, Raul G. Nogueira

Bibliographic record

VenueJournal of NeuroInterventional Surgery · 2014
Typearticle
Languageen
FieldMedicine
TopicAcute Ischemic Stroke Management
Canadian institutionsnot available
Fundersnot available
KeywordsPenumbraMedicineThrombolysisIntracerebral hemorrhageStroke (engine)Univariate analysisSingle CenterCerebral infarctionInternal medicineCardiologyMyocardial infarctionIschemiaMultivariate analysisSubarachnoid hemorrhage

Abstract

fetched live from OpenAlex

BACKGROUND AND PURPOSE: Higher reperfusion rates have been established with endovascular treatment of acute ischemic stroke (AIS). There are limited data on the comparative performance of mechanical thrombectomy devices. METHODS: A retrospective single-center analysis was undertaken of all consecutive patients who underwent thrombectomy using Merci, Penumbra or stent retrievers (SR) from September 2010 to November 2012. Baseline characteristics, rates of successful recanalization (modified Thrombolysis in Cerebral Infarction (mTICI) score 2b-3), symptomatic intracerebral hemorrhage (sICH), final infarct volume, 90-day mortality and independent functional outcomes at 90 days were compared across the three devices. RESULTS: Our cohort included 287 patients. There were mild imbalances in baseline characteristics with trends towards higher National Institutes of Health Stroke Scale (NIHSS) score in patients in the Merci group (SR=18 vs Merci=21 vs Penumbra=19, p=0.06) and lower Alberta Stroke Program Early CT Score (ASPECTS) in patients in the SR group (>7: SR=51% vs Merci=61% vs Penumbra=62%, p=0.12). On univariate analysis there were no differences in the rate of sICH (SR=7% vs Merci=7% vs Penumbra=6%, p=0.921) and infarct volume (SR=61.5 mL vs Merci=69.5 mL vs Penumbra=59.2 mL, p=0.621). Trends towards better functional outcomes were found with Penumbra and SR vs Merci (41% vs 36% vs 25%, respectively, p=0.079). Complete or near complete reperfusion (mTICI 2b-3) was higher in the SR and Penumbra groups than in the Merci group (86% vs 78% vs 70%, respectively, p=0.027). Binary logistic regression showed that SR was an independent predictor of good functional outcome (OR 2.27, 95% CI 1.018 to 5.048; p=0.045). CONCLUSIONS: Although our initial data confirm the superiority of SR technology over the Merci device, there was no significant difference in near complete/complete reperfusion, final infarct volumes or clinical outcomes between SR and Penumbra thromboaspiration.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.001
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.631

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0020.001
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.002
Bibliometrics0.0010.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.057
GPT teacher head0.347
Teacher spread0.290 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations11
Published2014
Admission routes1
Has abstractyes

Explore more

Same venueJournal of NeuroInterventional SurgerySame topicAcute Ischemic Stroke ManagementFrench-language works237,207