MétaCan
Menu
Back to cohort
Record W2153661071 · doi:10.1177/0267659110371557

What is optimal flow using a mini-bypass system?

2010· article· en· W2153661071 on OpenAlexaff
Philip Fernandes, James MacDonald, A. Cleland, G. Walsh, Richard Mayer

Bibliographic record

VenuePerfusion · 2010
Typearticle
Languageen
FieldMedicine
TopicCardiac and Coronary Surgery Techniques
Canadian institutionsLondon Health Sciences Centre
Fundersnot available
KeywordsMedicineCardiopulmonary bypassCardiac indexMean arterial pressureCardiac surgeryCardiac outputAnesthesiaCentral venous pressureCardiologyHemodynamicsBlood pressureHeart rateInternal medicine

Abstract

fetched live from OpenAlex

The purpose of this study is to determine the appropriate arterial pump flow /cardiac index (CI) utilizing a mini-bypass system. The unique feature of most mini-bypass systems is that the centrifugal pump combines the function of kinetic venous drainage with arterial pump flow. Therefore, if drainage is reduced, arterial pump flow is also reduced. Managing this system can present challenges to the clinical perfusionist. We reviewed fifteen cases, using the Medtronic Resting Heart System (RHS). This retrospective study examined the arterial pump flow, measured as cardiac index (CI), mean arterial pressure, inlet venous saturation, urine output, vasopressor use, and lactate production during routine cardiac surgery. The mean cardiac index for all patients was 1.90 +/- 0.14, range 1.63-2.08 L/min/m(2). The mean hemoglobin on cardiopulmonary bypass (CPB) was 10.6 +/- 1.2, with a range of 9.2-13.3 g/dL. The lactate produced on CPB was 2.03 +/-0.67 with a range of 1.5-3.5 mmol/L. The mean change in lactate measured from pre CPB to post CPB was 0.85 +/- 0.71 with a median lactate of 0.6 mmol/L. The venous saturation was 65.53 +/- 6.03% with a median of 65% and a range of 57-82%. The mean arterial pressure was 67.04 +/- 10.45 mmHg with a median of 62.5 mmHg. The median urine output was 125 mls. The vasopressor median was 2200 microg. All patients were maintained on CPB with a mean nasopharyngeal temperature of 35.43 degrees Celsius. Despite using lower than predicted flows, it would appear that adequate perfusion is provided. The higher hemoglobin content achieved through reduced hemodilution and reduced inflammation appears to enable this system to deliver adequate flow and perfusion at reduced cardiac indices. This research provides evidence which challenges longstanding beliefs that a cardiac index of 2.4 L/min/m(2) is required for all cases.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame machine prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. The Gemma side is a direct model label for every work in the frame, read from the title-only record. The Codex side is a classifier learned from the 10,348 direct Codex labels and calibrated to design-weighted sample rates; fields without enough sample support carry no Codex call. Candidate is the union of the two sides; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels.

metaresearch head score (Codex)0.002
metaresearch head score (Gemma)0.008
Version: metacan-v3-hybrid-931329e0061cValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Observational · Consensus signal: Observational
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.002
Threshold uncertainty score0.012

Distilled classifier scores by category (both heads)

CategoryCodexGemma
Metaresearch0.0020.008
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0010.000
Bibliometrics0.0020.001
Science and technology studies0.0010.001
Scholarly communication0.0020.003
Open science0.0010.000
Research integrity0.0020.001
Insufficient payload (model declined to judge)0.0020.001

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.014
GPT teacher head0.275
Teacher spread0.261 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one source (direct Gemma or distilled Codex), not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designObservational
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations8
Published2010
Admission routes1
Has abstractyes

Explore more

Same venuePerfusionSame topicCardiac and Coronary Surgery TechniquesFrench-language works237,207