What is the best approach in a patient with a failed aortic bioprosthetic valve: transcatheter aortic valve replacement or redo aortic valve replacement?: Table 1:
Why this work is in the frame
A frame that forgets how it found something cannot be audited. These are the routes that admitted this work.
Bibliographic record
Abstract
A best evidence topic in cardiac surgery was written according to a structured protocol. The question addressed was whether transcatheter aortic valve-in-valve replacement (viv-TAVR) or redo aortic valve replacement (rAVR) is the best strategy in a patient with a degenerative bioprosthetic aortic valve. Altogether, 162 papers were found using the reported search, of which 12 represented the best evidence to answer the question. The authors, journal, date, country of publication, patient group, study type, outcomes and results of papers are tabulated. The results of the studies provided interesting results. All the studies are retrospective. Four papers reported the results of redo aortic valve replacement in patients with failed aortic bioprosthetic valve, six papers demonstrated their results with transcatheter aortic valve-in-valve replacement for the same indication and two papers reported their propensity-matched analysis of outcomes between viv-TAVR and rAVR in patients with previous cardiac surgery. Thirty-day mortality for rAVR was 2.3-15.5% and 0-17% for viv-TAVR. For rAVR, survival rate at 30 days was 83.6%, 76.1% at 1 year, 70.8% at 3 years, at 51.3-66% at 5 years, 61% at 8 years and 61.5% at 10 years. For viv-TAVR, the overall Kaplan-Meier survival rate at 1 year was 83.2%. After viv-TAVR at 1 year, 86.2% of surviving patients were at New York Heart Association (NYHA) class I/II. The complications after rAVR were stroke (4.6-5.8%), reoperation for bleeding (6.9-9.7%), low-cardiac output syndrome (9.9%) whereas complications after viv-TAVR at 30 days were major stroke (1.7%), aortic regurgitation of at least moderate degree (25%), new permanent pacemaker implantation rate (0-11%), ostial coronary obstruction (2%), need for implantation of a second device (5.7%) and major vascular complications (9.2%). It is noteworthy to mention that there is a valve-in-valve application that provides information to surgeons for choosing the correct size of the TAVR valve. Transcatheter aortic valve-in-valve procedures are clinically effective, at least in the short term, and could be an acceptable approach in selected high-risk patients with degenerative bioprosthetic valves. Redo AVR achieves acceptable medium and long-term results. Both techniques could be seen as complementary approaches for high-risk patients.
Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.
Full frame distilled prediction
Teacher imitationNot calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.
Codex and Gemma teacher scores by category
| Category | Codex | Gemma |
|---|---|---|
| Metaresearch | 0.002 | 0.000 |
| Meta-epidemiology (narrow) | 0.002 | 0.001 |
| Meta-epidemiology (broad) | 0.006 | 0.020 |
| Bibliometrics | 0.001 | 0.001 |
| Science and technology studies | 0.000 | 0.000 |
| Scholarly communication | 0.000 | 0.001 |
| Open science | 0.000 | 0.000 |
| Research integrity | 0.000 | 0.001 |
| Insufficient payload (model declined to judge) | 0.000 | 0.000 |
Machine scores (provisional)
The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.
Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.
score_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it