MétaCan
Menu
Back to cohort
Record W2155226477 · doi:10.1148/radiol.11102327

Congenital Heart Disease: Cardiovascular MR Imaging by Using an Intravascular Blood Pool Contrast Agent

2011· article· en· W2155226477 on OpenAlexaff
Marcus R. Makowski, Andrea J. Wiethoff, Sergio Uribe, Victoria Parish, René M. Botnar, Aaron Bell, Christoph Kiesewetter, Philipp Beerbaum, Christian Jansen, Reza Razavi, Tobias Schaeffter, Gerald Greil

Bibliographic record

VenueRadiology · 2011
Typearticle
Languageen
FieldMedicine
TopicAdvanced MRI Techniques and Applications
Canadian institutionsSt. Thomas Hospital
FundersNational Institute for Health and Care Research
KeywordsMedicineSteady-state free precession imagingNuclear medicineRadiologyFlip angleImage qualityContrast (vision)Magnetic resonance imaging

Abstract

fetched live from OpenAlex

PURPOSE: To compare the image quality and diagnostic performance of a contrast agent-specific inversion-recovery (IR) steady-state free precession (SSFP) magnetic resonance (MR) imaging sequence performed by using an intravascular contrast agent (gadofosveset trisodium) with those of a commonly used T2-prepared SSFP sequence performed by using an extravascular (gadopentetate dimeglumine) and an intravascular (gadofosveset trisodium) contrast agent in patients with congenital heart disease (CHD). MATERIALS AND METHODS: The local ethics committee and the United Kingdom Medicines and Healthcare products Regulatory Agency approved this study. Patient informed consent was obtained. Twenty-three patients with CHD were examined by using a 1.5-T MR imaging unit and a 32-channel coil. Gadopentetate dimeglumine and gadofosveset trisodium were used in the same patient on consecutive days. Vessel wall sharpness, contrast-to-noise ratios (CNRs), image quality, and diagnostic performance achieved by using the IR SSFP sequence with gadofosveset trisodium were compared with those achieved by using the T2-prepared SSFP sequence with gadopentetate dimeglumine and gadofosveset trisodium and with those achieved at respective contrast material-enhanced MR angiographic examinations. The Wilcoxon rank sum test was used to compare categoric variables; t tests were used to compare continuous variables. RESULTS: Use of the IR SSFP sequence with gadofosveset trisodium significantly improved vessel wall sharpness, CNRs, and image quality (P < .05 for all) for all investigated intra- and extracardiac structures compared with the T2-prepared SSFP sequence with gadopentetate dimeglumine and gadofosveset trisodium and the respective contrast-enhanced MR angiographic examinations. With use of the IR SSFP sequence with gadofosveset trisodium, new, unsuspected diseases (five [22%] of 23) were diagnosed, while other diseases could be excluded (15 [65%] of 23). Information available from echocardiography (n = 23), conventional angiography (n = 4), and/or surgery (n = 1) confirmed all diagnoses. CONCLUSION: IR SSFP with gadofosveset trisodium improved image quality and diagnostic performance, allowing a more accurate and complete assessment of cardiovascular anatomy in patients with CHD compared with T2-prepared SSFP with gadopentetate dimeglumine and gadofosveset trisodium and respective contrast-enhanced MR angiographic examinations.

Fetched live from OpenAlex and de-inverted. Abstracts are not stored in this database: the inverted indexes are 8.6 GB of the frame’s 9.3 GB of text, and the host has 13 GB free.

How this classification was reachedexpand

Full frame distilled prediction

Teacher imitation

Not calibrated prevalence, not ground truth. Human validation pending. Learned from the 10,348 direct Codex labels and 10,348 direct Gemma labels. Candidate is the union of thresholded teacher heads; consensus is their intersection. These outputs are machine_predicted_unvalidated and are not human labels or direct frontier model labels.

metaresearch head score (Codex)0.000
metaresearch head score (Gemma)0.000
Version: codex-gemma-dda1882f352aValidation status: machine_predicted_unvalidated
Candidate categoriesnone
Consensus categoriesnone
DomainCandidate signal: none · Consensus signal: none
Study designCandidate signal: Bench or experimental · Consensus signal: none
GenreCandidate signal: Empirical · Consensus signal: Empirical
Teacher disagreement score0.584
Threshold uncertainty score0.624

Codex and Gemma teacher scores by category

CategoryCodexGemma
Metaresearch0.0000.000
Meta-epidemiology (narrow)0.0000.000
Meta-epidemiology (broad)0.0000.000
Bibliometrics0.0000.000
Science and technology studies0.0000.000
Scholarly communication0.0000.000
Open science0.0000.000
Research integrity0.0000.000
Insufficient payload (model declined to judge)0.0000.000

Machine scores (provisional)

The two teacher heads of the student model, read on this work. A score orders the frame for review; it never asserts a category, and the validation status ships verbatim with every row.

Baseline scores from an immature model (maturity gate not passed, 7 training rounds). Scores rank; they never assert a category.

Opus teacher head0.024
GPT teacher head0.277
Teacher spread0.253 · how far apart the two teachers sit on this one work
Validation statusscore_only:v0-immature-baseline · verbatim from the scoring run: score_only means the number may rank works, and no category label ships from it

Classification

machine, unvalidated

Machine predicted; a candidate call from one teacher head, not a consensus.

The models applied no category: nothing in the taxonomy fit this work.
Study designBench or experimental
Domainnot available
GenreEmpirical

How this classification was reached, model by model and score by score, is at the end of the page under "How this classification was reached".

Quick stats

Citations43
Published2011
Admission routes1
Has abstractyes

Explore more

Same venueRadiologySame topicAdvanced MRI Techniques and ApplicationsFrench-language works237,207